In the present study we report the standardization of an immunoradiometric assay (IRMA) for detection of Paracoccidioides brasiliensis circulating antigens that could be useful in the diagnosis and prognosis of paracoccidioidomycosis. For this purpose we studied the reactivities of P. brasiliensis and other mycotic antigens with rabbit polyclonal anti-P. brasiliensis antibodies (immunoglobulin G) in order to evaluate the sensitivity and specificity of an IRMA for detecting P. brasiliensis antigens. The results were compared with those obtained by the double immunodiffusion test, the standard technique for the serodiagnosis of paracoccidioidomycosis. By using the immunoglobulin G fraction of rabbit antisera (900 ng per well), it was possible to detect up to 3.6 ng (0.12 micrograms/ml) of cellular antigen and 360 ng (12 micrograms/ml) of metabolic antigen in contrast to the double immunodiffusion test that could detect only 12 micrograms (1.2 mg/ml) of both antigens. IRMA was shown to be feasible and very sensitive and may therefore help, together with clinical data, in establishing early diagnosis and assessing disease activity. It could also allow the study of relationships between P. brasiliensis circulating antigens and host defense mechanisms during the disease.
在本研究中,我们报告了一种用于检测巴西副球孢子菌循环抗原的免疫放射分析(IRMA)的标准化方法,该方法可能有助于副球孢子菌病的诊断和预后评估。为此,我们研究了巴西副球孢子菌和其他真菌抗原与兔多克隆抗巴西副球孢子菌抗体(免疫球蛋白G)的反应性,以评估用于检测巴西副球孢子菌抗原的IRMA的敏感性和特异性。将结果与通过双免疫扩散试验(副球孢子菌病血清诊断的标准技术)获得的结果进行比较。通过使用兔抗血清的免疫球蛋白G组分(每孔900 ng),能够检测到高达3.6 ng(0.12μg/ml)的细胞抗原和360 ng(12μg/ml)的代谢抗原,而双免疫扩散试验只能检测到两种抗原各12μg(1.2mg/ml)。IRMA被证明是可行且非常敏感的,因此与临床数据一起可能有助于建立早期诊断和评估疾病活动。它还可以用于研究疾病期间巴西副球孢子菌循环抗原与宿主防御机制之间的关系。