Suppr超能文献

Value of intravascular ultrasound imaging in following up patients with replacement of the ascending aorta for acute type A aortic dissection.

作者信息

Hu Wei, Schiele François, Meneveau Nicolas, Seronde Marie-France, Legalery Pierre, Caulfield Fiona, Bonneville Jean-François, Chocron Sidney, Bassand Jean-Pierre

机构信息

Department of Cardiology, Min Hang Central Hospital, Shanghai 201100, China.

出版信息

Chin Med J (Engl). 2008 Nov 5;121(21):2139-43.

Abstract

BACKGROUND

The value of intravascular ultrasound (IVUS) imaging in patients with replacement of the ascending aorta for acute type A aortic dissection (AD) is unknown. The purpose of this study was to assess the potential use of IVUS imaging in this setting.

METHODS

From September 2002 to July 2005, IVUS imaging with a 9 MHz probe was performed in a series of 16 consecutive patients with suspected or established AD. This study focused on 5 of them with replacement of the ascending aorta for acute type A AD. Among these 5 patients, other imaging modalities including aortography, spiral computed tomography, magnetic resonance imaging and transesophageal echocardiography were performed in 5, 3, 3 and 1 patients, respectively.

RESULTS

There were no complications related to IVUS imaging. For the replaced graft, as other imaging modalities, IVUS could identify all 5 grafts, the proximal and the distal anastomoses, and the ostia of the reimplanted coronary arteries. In 2 cases, IVUS detected 2 peri-graft pseudo-aneurysms (1 per case), which were also detected by magnetic resonance imaging but omitted by aortography. For the residual dissection, IVUS had similar findings as other imaging modalities in detecting the patency (5/5), the longitudinal and the circumferential extent, the thrombus (4/5), the recurrent dissection (1/5) and an aneurysm distal to the graft (5 in 4 patients). However, it detected more intimal tears and side branch involvements than other imaging modalities (15 vs 10 and 3 vs 1, respectively).

CONCLUSIONS

In following-up patients with replacement of the ascending aorta for acute type A AD, IVUS imaging can provide complete information of the replaced graft and the residual dissection. So, IVUS imaging may be considered when the four current frequently used imaging modalities can not supply sufficient information or there are some discrepancies between them.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验