Stecco A, Romano G, Negru M, Volpe D, Saponaro A, Costantino S, Sacchetti G, Inglese E, Alabiso O, Carriero A
SCDU Radiologia, Università del Piemonte Orientale A. Avogadro, C.so Mazzini 18, 28100, Novara, Italy.
Radiol Med. 2009 Feb;114(1):1-17. doi: 10.1007/s11547-008-0348-4. Epub 2008 Dec 11.
The aim of this pilot study was to compare positron emission tomography computed tomography (PET-CT) and whole-body DWIBS in staging oncological patients to determine the staging accuracy of whole-body DWIBS.
We initiated a prospective, blinded investigation on 29 patients affected by oncological diseases (n=14) or lymphoma (n=15), who underwent fluorodeoxyglucose (FDG)-based PET-CT and whole-body DWIBS for restaging purposes. Magnetic resonance (MR) imaging was conducted with a multistack (n=4) DWIBS pulse sequence. Images were read independently by two experienced radiologists and one nuclear physician. Statistical analysis assessed interobserver agreement and diagnostic accuracy.
Whole-body DWIBS had a room occupation time of 20 min. Mean postprocessing time was 15 min (range 10-17 min). Mean reading time was 20 min for reader 1 (range 15-25 min) and 18 min for reader 2 (range 13-22 min). Interobserver agreement was almost perfect (=0.93). Reader 1 had a sensitivity of 89.07%, a specificity of 98.5%, and an accuracy of 97.65%, with a positive predictive value (PPV) of 85.48% and a negative predictive value (NPV) of 98.91%. Reader 2 had a sensitivity of 87.39%, a specificity of 98.39% and a diagnostic accuracy of 97.8%, with a PPV of 88.13% and a NPV of 98.75%.
The whole-body DWIBS protocol provided a fast whole-body examination with high specificity and NPV. One major bias of the study was the inclusion of patients with diffuse disease and advanced disease stage and the heterogeneity of the neoplastic diseases included.
本初步研究的目的是比较正电子发射断层扫描计算机断层扫描(PET-CT)和全身扩散加权体部成像(DWIBS)在肿瘤患者分期中的应用,以确定全身DWIBS的分期准确性。
我们对29例患有肿瘤疾病(n = 14)或淋巴瘤(n = 15)的患者进行了一项前瞻性、盲法研究,这些患者接受了基于氟脱氧葡萄糖(FDG)的PET-CT和全身DWIBS检查以进行再分期。采用多层面(n = 4)DWIBS脉冲序列进行磁共振(MR)成像。图像由两名经验丰富的放射科医生和一名核医学医生独立阅片。统计分析评估了观察者间的一致性和诊断准确性。
全身DWIBS的扫描时间为20分钟。平均后处理时间为15分钟(范围10 - 17分钟)。阅片者1的平均阅片时间为20分钟(范围15 - 25分钟),阅片者2的平均阅片时间为18分钟(范围13 - 22分钟)。观察者间的一致性几乎为完美(κ = 0.93)。阅片者1的敏感性为89.07%,特异性为98.5%,准确性为97.65%,阳性预测值(PPV)为85.48%,阴性预测值(NPV)为98.91%。阅片者2的敏感性为87.39%,特异性为98.39%,诊断准确性为97.8%,PPV为88.13%,NPV为98.75%。
全身DWIBS方案提供了一种快速的全身检查,具有高特异性和NPV。该研究的一个主要偏倚是纳入了患有弥漫性疾病和晚期疾病阶段的患者以及所纳入肿瘤疾病的异质性。