Suppr超能文献

采用背景体部信号抑制的全身扩散加权成像在骨与骨外转移瘤检测中的应用

Whole-body diffusion-weighted imaging with background body signal suppression in the detection of osseous and extra-osseous metastases.

作者信息

Razek Ahmed Abdel, Tawfik Ahmed, Rahman Mariam Abdel, Teima Saleh

机构信息

Department of Diagnostic Radiology, Mansoura Faculty of Medicine, Mansoura University, Mansoura, Egypt.

Department of Radiotherapy, Mansoura Faculty of Medicine, Mansoura University, Mansoura, Egypt.

出版信息

Pol J Radiol. 2019 Nov 12;84:e453-e458. doi: 10.5114/pjr.2019.90057. eCollection 2019.

Abstract

PURPOSE

To assess the reproducibility of detection of osseous and extra-osseous metastases in cancer patients using whole-body diffusion-weighted imaging with background body signal suppression (WB-DWIBS).

MATERIAL AND METHODS

A prospective study was conducted on 39 consecutive patients (21 females, 18 males; mean age 48 years) with metastases, who underwent WB-DWIBS on a 1.5-T MR scanner. Image analysis was performed independently by two blinded observers. Inter-observer agreement was assessed for the detection of osseous (spinal, appendicular) and extra-osseous (hepatic, pulmonary, nodal, and peritoneal) metastases.

RESULTS

The overall inter-observer agreement of WB-DWIBS in the detection of osseous and extra-osseous metastases was excellent (κ = 0.887, agreement = 94.44%, = 0.001). There was excellent inter-observer agreement of both observers for the detection of osseous spinal (κ = 0.846, agreement = 92.3%), osseous appendicular (κ = 0.898, agreement = 94.8 %), hepatic (κ = 0.847, agreement = 92.3%), pulmonary (κ = 0.938, agreement = 97.4%), nodal metastases (κ = 0.856, agreement = 94.9%), and peritoneal metastasis (κ = 0.772, agreement = 94.9%).

CONCLUSION

We concluded that WB-DWIBS is reproducible for detection of osseous and extra-osseous metastases in cancer patients.

摘要

目的

利用背景体素信号抑制的全身扩散加权成像(WB-DWIBS)评估癌症患者骨转移和骨外转移检测的可重复性。

材料与方法

对39例连续的有转移灶的患者(21例女性,18例男性;平均年龄48岁)进行前瞻性研究,这些患者在1.5-T磁共振成像扫描仪上接受WB-DWIBS检查。由两名不知情的观察者独立进行图像分析。评估观察者间在检测骨(脊柱、四肢)和骨外(肝脏、肺、淋巴结和腹膜)转移方面的一致性。

结果

WB-DWIBS在检测骨转移和骨外转移方面观察者间的总体一致性极佳(κ = 0.887,一致性 = 94.44%,P = 0.001)。两名观察者在检测脊柱骨转移(κ = 0.846,一致性 = 92.3%)、四肢骨转移(κ = 0.898,一致性 = 94.8%)、肝脏转移(κ = 0.847,一致性 = 92.3%)、肺转移(κ = 0.938,一致性 = 97.4%)、淋巴结转移(κ = 0.856,一致性 = 94.9%)和腹膜转移(κ = 0.772,一致性 = 94.9%)方面均具有极佳的观察者间一致性。

结论

我们得出结论,WB-DWIBS在检测癌症患者的骨转移和骨外转移方面具有可重复性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/394e/6964352/bdae60171957/PJR-84-38698-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验