Dural bridge sutures to prevent sinking of dural substitutes: technical note.

作者信息

Balasubramanian Chandramouli, Coley Emma, Whittle Ian Roger

机构信息

Department of Clinical Neurosciences, Western General Hospital, Edinburgh, Scotland, UK.

出版信息

Acta Neurochir (Wien). 2009 Feb;151(2):155-7. doi: 10.1007/s00701-008-0167-3. Epub 2008 Dec 14.

Abstract

INTRODUCTION

Following Simpson Grade 1 excision of large convexity meningioma there is often a need for synthetic dural substitutes.

DISCUSSION

One problem with some of these grafts is that they lack tensile strength when wet and therefore sink into the cavity left following removal of the meningioma.

CONCLUSION

A simple method to prevent 'sinking' or sagging of such synthetic dural grafts is described and illustrated.