Suppr超能文献

由于假体头尺寸与股骨颈直径比例不佳,髋关节表面置换术的活动范围受限。

Limited range of motion of hip resurfacing arthroplasty due to unfavorable ratio of prosthetic head size and femoral neck diameter.

作者信息

Kluess Daniel, Zietz Carmen, Lindner Tobias, Mittelmeier Wolfram, Schmitz Klaus-Peter, Bader Rainer

机构信息

Department of Orthopedics, Institute for Biomedical Engineering, University of Rostock, Germany.

出版信息

Acta Orthop. 2008 Dec;79(6):748-54. doi: 10.1080/17453670810016803.

Abstract

BACKGROUND AND PURPOSE

Hip resurfacing arthroplasty is being used more and more frequently. The small ratio in size between the resurfaced femoral head and the relatively thick femoral neck raises the question of whether the range of motion is sufficient, particularly with regard to the high mobility required by younger patients. We analyzed motion in a CAD model.

METHODS

Three-dimensional CAD models of the natural hip were created from CT scans and 8 designs of hip resurfacing prostheses (head diameter between 42 mm and 54 mm combined with a hemispherical cup) were implanted in a virtual sense. We simulated 3 different leg positions and the range of motion was evaluated, considering five different implant positions.

RESULTS

The range of motion of the hip resurfacing designs analyzed was far below the range of motion of stemmed total hip prostheses. None of the resurfacing prostheses provided flexion movements of 90 degrees without impingement. The average range of motion of hip resurfacing arthroplasty was 31-48 degrees below the range of motion of a stemmed total hip replacement with 32-mm head diameter.

INTERPRETATION

The range of motion of the hip resurfacing designs examined was substantially less than that of a conventional total hip prosthesis. Since impingement of the femoral neck on the acetabular component increases the risk of neck fractures, of dislocation and of subsequent implant loosening, the design and position of the implant should be considered before using hip resurfacing arthroplasty as a standard treatment for younger patients.

摘要

背景与目的

髋关节表面置换术的应用越来越频繁。表面置换的股骨头与相对较粗的股骨颈尺寸比例较小,这引发了关于活动范围是否足够的问题,尤其是对于年轻患者所需的高活动度而言。我们在计算机辅助设计(CAD)模型中分析了运动情况。

方法

根据CT扫描创建天然髋关节的三维CAD模型,并虚拟植入8种髋关节表面置换假体设计(股骨头直径在42毫米至54毫米之间,搭配半球形髋臼杯)。我们模拟了3种不同的腿部位置,并考虑5种不同的假体位置评估了活动范围。

结果

所分析的髋关节表面置换设计的活动范围远低于带柄全髋关节假体的活动范围。没有一种表面置换假体能在无撞击的情况下提供90度的屈曲运动。髋关节表面置换术的平均活动范围比头直径为32毫米的带柄全髋关节置换术的活动范围低31至48度。

解读

所检查的髋关节表面置换设计的活动范围明显小于传统全髋关节假体。由于股骨颈与髋臼部件的撞击会增加颈部骨折、脱位以及随后假体松动的风险,在将髋关节表面置换术作为年轻患者的标准治疗方法之前,应考虑假体的设计和位置。