Suppr超能文献

腹腔镜胃束带术术后一种罕见的并发症:连接管穿入肾门。

A rare complication after laparoscopic gastric banding: connecting-tube penetration into the hilus of the kidney.

作者信息

Sneijder R, Cense H A, Hunfeld M, Breederveld R S

机构信息

Department of Surgery, Red Cross Hospital, Vondellaan 13, Beverwijk, The Netherlands.

出版信息

Obes Surg. 2009 Apr;19(4):531-3. doi: 10.1007/s11695-008-9777-3. Epub 2008 Dec 17.

Abstract

Laparoscopic adjustable gastric banding is a common operation for morbid obesity. Late complications mainly originate from either the injection port (dislocation, infection, leakage) or the gastric band (pouch dilatation, slippage, leakage, gastric erosion). Complications from the tube, connecting the port with the band, are rarely described. We report the penetration of a loose connecting tube into the kidney 8 months after removal of an infected injection port.

摘要

腹腔镜可调节胃束带术是治疗病态肥胖的常见手术。晚期并发症主要源于注射端口(脱位、感染、渗漏)或胃束带(胃囊扩张、滑脱、渗漏、胃糜烂)。连接端口与束带的导管引发的并发症鲜有报道。我们报告了1例在移除感染的注射端口8个月后,松动的连接管刺入肾脏的病例。