Comparison of performance of classical clinical chemistry analysers with test-strip devices (Reflotron) and those based on film technology (Vitros) in external quality assessment (EQA) surveys.

作者信息

Wood William Graham

机构信息

Reference Laboratory, Instand e. V., Düsseldorf Germany.

出版信息

Clin Lab. 2008;54(9-10):359-77.

PMID:19097494
Abstract

This article reports on the performance of two "dry" chemistry devices, (Reflotron, Roche Diagnostics and Vitros, Johnson & Johnson) and compared them with classical "wet" chemistry analysers in four commercially produced quality assessment samples (Roche PNU and PPU and Seronorm Human and Human High Controls) sent repeatedly over a 12-month observation period. Eleven analytes (including five enzymes) were studied, eight of which had target values set by reference method procedures. The results showed that both devices gave comparative results for the same sample sent in different EQA-surveys. Statistically significant differences which occurred were due to the high precision of measurement with a minimal shift in the measured concentrations. They had no clinical relevance in interpretation of results. Comparisons between "dry" and "wet" chemistry results for the same analyte were almost always statistically significantly different and often large enough to influence the clinical interpretation of results. Examples here were glucose and uric acid measured with the Reflotron and compared with other Roche devices (Cobas, Hitachi). The Vitros showed deviant values for urea and creatinine, when compared with other measuring devices using liquid reagents. Differences seen were constant over time, but must be seen in context with the matrices of the samples sent. The results show the long term stability of both reagents and test kits, a necessary prerequisite for long-term controlling of precision and indirectly accuracy of patient measurements.

摘要

相似文献

1
Comparison of performance of classical clinical chemistry analysers with test-strip devices (Reflotron) and those based on film technology (Vitros) in external quality assessment (EQA) surveys.
Clin Lab. 2008;54(9-10):359-77.
2
A multicentre evaluation of the Ektachem DT60-, Reflotron- and Seralyzer III systems.对Ektachem DT60、Reflotron和Seralyzer III系统的多中心评估。
Eur J Clin Chem Clin Biochem. 1992 Sep;30(9):547-83.
3
Experience with an external quality assessment programme for point-of-care-testing (POCT) devices for the determination of blood glucose.用于测定血糖的即时检测(POCT)设备的外部质量评估计划经验。
Clin Lab. 2003;49(3-4):151-9.
4
Problems with the external quality assessment of accuracy of point of care devices (POCD) for blood glucose are independent of sample composition.用于血糖检测的即时检测设备(POCD)准确性的外部质量评估问题与样本成分无关。
Clin Lab. 2006;52(7-8):345-51.
5
[Dry chemistry in the clinical laboratory: how reliable is it?].
Schweiz Med Wochenschr. 1992 Dec 26;122(51-52):1980-4.
6
[Clinical evaluation of a test strip for measuring creatinine in capillary blood of children].
Padiatr Padol. 1991;26(5):229-33.
7
Evaluation of five new liquid stable applications on the Roche Cobas Integra.
Eur J Clin Chem Clin Biochem. 1997 Nov;35(11):877-80.
8
[Alpha 2 macroglobulin immunoturbidimetric assays (DakoCytomation reagents) on Roche Diagnostic analysers (Modular P, Cobas Integra). Application to FibroTest-Actic-Test].罗氏诊断分析仪(模块化P型、Cobas Integra型)上的α2巨球蛋白免疫比浊法检测(达科西玛试剂)。在FibroTest-Actic-Test中的应用
Ann Biol Clin (Paris). 2005 Jul-Aug;63(4):385-95.
9
[Dry chemistry of reagent strips].[试剂条的干化学法]
Schweiz Med Wochenschr. 1987 May 30;117(22):833-40.
10
Dry chemistry: an assessment of the BCL Reflotron system.
Med Lab Sci. 1990 Oct;47(4):263-71.

引用本文的文献

1
Retrospective analysis of 55,769 HbA1c EQA results obtained from professional laboratories and medical offices participating in surveys organized by two European EQA centers over a nine-year period.对参与两个欧洲外部质量评估(EQA)中心组织的调查的专业实验室和医疗办公室的 55769 份 HbA1c EQA 结果进行回顾性分析,历时九年。
J Clin Lab Anal. 2011;25(5):337-43. doi: 10.1002/jcla.20482.