外周动脉顺应性相关指标对血管收缩刺激的差异性反应。

Differential response of peripheral arterial compliance-related indices to a vasoconstrictive stimulus.

作者信息

Guerrisi Maria, Vannucci Italo, Toschi Nicola

机构信息

Sezione di Fisica Medica, Facoltá di Medicina e Chirurgia, Università degli Studi di Roma Tor Vergata, Rome, Italy.

出版信息

Physiol Meas. 2009 Jan;30(1):81-100. doi: 10.1088/0967-3334/30/1/006. Epub 2008 Dec 22.

Abstract

Peripheral arterial elastic properties are greatly affected by cardiovascular as well as other pathologies, and their assessment can provide useful diagnostic indicators. The photoplethysmographic technique can provide finger blood volume and pressure waveforms non-invasively, which can then be processed statically or beat-to-beat to characterize parameters of the vessel wall mechanics. We employ an occlusion-deflation protocol in 48 healthy volunteers to study peripheral artery compliance-related indices over positive and negative transmural pressure values as well as under the influence of a valid vasoconstrictor (cigarette smoking). We calculate beat-to-beat indices (compliance index CI, distensibility index DI, three viscoelastic model parameters (compliance C, viscosity R and inertia L), pressure-volume loop areas A and damping factor DF as well as symmetrical (C(max)) and asymmetrical (C(A)(max)) static compliance estimates, and their distributions over transmural pressure. All distributions are bell-shaped and centred on negative transmural pressure values. Distribution heights were significantly lower in the smoking group (w.r.t. the non-smoking group) for C, CI, DI and significantly higher in R and DF. The estimated volume signal time lag was also significantly lower in the smoking group. Left and right distribution widths were significantly different in all parameters/groups but DI (both groups), C(A)(max), A (smoking group) and L (non-smoking group), and positions of maxima/minima were significantly altered in C(A)(max), R and DF. C, DF and CI are seen to be most sensitive under this protocol, while C(max) and C(A)(max) are seen to be insensitive. These quantities provide complementary, time- and transmural pressure-dependent information about arterial wall mechanics, and the choice of index should depend on the physiological conditions at hand as well as relevant time resolution and transmural pressure range.

摘要

外周动脉弹性特性受到心血管疾病以及其他病理状况的极大影响,对其进行评估可提供有用的诊断指标。光电容积描记技术能够无创地提供手指血容量和压力波形,然后可对其进行静态或逐搏处理,以表征血管壁力学参数。我们对48名健康志愿者采用阻断 - 放气方案,研究在正、负跨壁压力值以及有效血管收缩剂(吸烟)影响下的外周动脉顺应性相关指标。我们计算逐搏指标(顺应性指数CI、扩张性指数DI、三个粘弹性模型参数(顺应性C、粘性R和惯性L)、压力 - 容积环面积A和阻尼因子DF)以及对称(C(max))和不对称(C(A)(max))静态顺应性估计值,以及它们在跨壁压力上的分布。所有分布均呈钟形,且以负跨壁压力值为中心。吸烟组的C、CI、DI分布高度显著低于非吸烟组,而R和DF的分布高度显著更高。吸烟组的估计容积信号时间滞后也显著更低。除DI(两组)、C(A)(max)、A(吸烟组)和L(非吸烟组)外,所有参数/组的左右分布宽度均存在显著差异,并且C(A)(max)、R和DF的最大值/最小值位置发生了显著变化。在此方案下,C、DF和CI最为敏感,而C(max)和C(A)(max)则不敏感。这些量提供了关于动脉壁力学的互补的、与时间和跨壁压力相关的信息,指标的选择应取决于手头的生理状况以及相关的时间分辨率和跨壁压力范围。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验