Trace amounts of prostaglandins (PGs) were selectively analysed without derivatization using supercritical fluid extraction (SFE) and open tubular column supercritical fluid chromatography (SFC). The specific compounds studied were prostaglandin F2 alpha (PGF2 alpha), esters of PGF2 alpha, prostaglandin F1 alpha) and prostaglandin E2 (PGE2). An open tubular column was used with carbon dioxide as the mobile phase and with universal flame ionization detection. Samples were introduced into the column by direct injection using a 1-microliter sample loop or by SFE with solute focusing. The 11 standard compounds were effectively separated within 35 min using a density program at constant temperature. The minimum detectable quantity (signal-to-noise ratio = 3) using the direct injection method was 9 ng for 15-propionate PGF2 alpha isopropyl ester. Using the extraction method, the sample size in the extraction cell was increased to 100 microliters, which made it possible to analyse compounds that were present in low concentrations. Aqueous PG samples were extracted from adsorbents onto which the samples had been loaded.
使用超临界流体萃取(SFE)和开管柱超临界流体色谱法(SFC),在不进行衍生化的情况下对痕量前列腺素(PGs)进行了选择性分析。所研究的特定化合物为前列腺素F2α(PGF2α)、PGF2α的酯、前列腺素F1α和前列腺素E2(PGE2)。使用开管柱,以二氧化碳作为流动相,并采用通用火焰离子化检测。样品通过使用1微升进样环直接进样或通过带有溶质聚焦的SFE引入柱中。使用恒温密度程序,11种标准化合物在35分钟内有效分离。使用直接进样法时,15-丙酸PGF2α异丙酯的最低检测量(信噪比 = 3)为9纳克。使用萃取法时,萃取池中样品量增加到100微升,这使得分析低浓度存在的化合物成为可能。从已加载样品的吸附剂上萃取水性PG样品。