Suppr超能文献

犬白内障超声乳化吸除术后植入三种不同人工晶状体后囊膜混浊及屈光状态的比较。

Comparison of capsular opacification and refractive status after placement of three different intraocular lens implants following phacoemulsification and aspiration of cataracts in dogs.

作者信息

Gift Barrett W, English Robert V, Nadelstein Brad, Weigt Anne K, Gilger Brian C

机构信息

Animal Eye Care Associates, Cary, North Carolina, USA.

出版信息

Vet Ophthalmol. 2009 Jan-Feb;12(1):13-21. doi: 10.1111/j.1463-5224.2009.00667.x.

Abstract

OBJECTIVE

To evaluate the effect of lens design and biomaterial on formation of posterior capsular opacification (PCO) and refractive correction. Animals studied Sixty dogs undergoing bilateral phacoemulsification for mature or diabetic cataracts.

PROCEDURES

One randomly selected eye received a rounded edge 41D polymethyl-methacrylate (PMMA) intraocular replacement lens (IOL) and the contralateral eye received either a squared edge 41D hydrophilic acrylic IOL (n = 35) or a squared edge 40D hydrophobic acrylic IOL (n = 25). At the (mean = 79 day) reexamination period, PCO was graded using direct slit-lamp observation and by masked observer evaluation of digital images of the IOLs. Streak retinoscopy and B-mode ultrasound were performed at this period.

RESULTS

The PCO score via direct slit-lamp was significantly lower for the hydrophilic acrylic IOL when compared to the PMMA IOL. Masked observer evaluation of digital images revealed that the acrylic IOLs had lower but generally not statistically significant PCO scores than the PMMA IOLs. Streak retinoscopy showed that the PMMA IOL was significantly closer to emmetropia (+0.44 D) when compared to either the hydrophilic acrylic (+0.96 D) or the hydrophobic acrylic (+1.2 D) IOLs. B-mode ultrasonography revealed the center of the hydrophilic acrylic IOL is 0.31 mm closer to the retina and the center of the hydrophobic acrylic IOL is 0.63 mm further from the retina when compared to the center of the PMMA to retina distance.

CONCLUSIONS

Square edged foldable acrylic IOLs show a predisposition towards generating slightly less PCO than round edged PMMA IOLs in the early postoperative period, however, both acrylic IOLs had greater persistent hyperopia than the PMMA IOLs.

摘要

目的

评估晶状体设计和生物材料对后囊膜混浊(PCO)形成及屈光矫正的影响。研究动物 60 只接受双侧超声乳化治疗成熟或糖尿病性白内障的犬。

方法

随机选择一只眼植入边缘圆润的 41D 聚甲基丙烯酸甲酯(PMMA)人工晶状体(IOL),对侧眼植入边缘方形的 41D 亲水性丙烯酸酯 IOL(n = 35)或边缘方形的 40D 疏水性丙烯酸酯 IOL(n = 25)。在(平均 = 79 天)复查期,通过直接裂隙灯观察及由遮蔽观察者对 IOL 的数字图像进行评估来对 PCO 进行分级。在此期间进行带状检影法和 B 型超声检查。

结果

与 PMMA IOL 相比,亲水性丙烯酸酯 IOL 通过直接裂隙灯检查的 PCO 评分显著更低。遮蔽观察者对数字图像的评估显示,丙烯酸酯 IOL 的 PCO 评分低于 PMMA IOL,但一般无统计学意义。带状检影法显示,与亲水性丙烯酸酯 IOL(+0.96 D)或疏水性丙烯酸酯 IOL(+1.2 D)相比,PMMA IOL 显著更接近正视(+0.44 D)。B 型超声检查显示,与 PMMA 至视网膜距离的中心相比,亲水性丙烯酸酯 IOL 的中心离视网膜近 0.31 mm,疏水性丙烯酸酯 IOL 的中心离视网膜远 0.63 mm。

结论

方形边缘可折叠丙烯酸酯 IOL 在术后早期显示出比圆形边缘 PMMA IOL 产生稍少 PCO 的倾向,然而,两种丙烯酸酯 IOL 比 PMMA IOL 有更大的持续性远视。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验