Suppr超能文献

光固化填充封闭剂对用树脂改性玻璃离子水门汀粘结的金属和陶瓷托槽剪切粘结强度的影响。

Effect of light-cured filled sealant on shear bond strength of metal and ceramic brackets bonded with a resin-modified glass ionomer cement.

作者信息

Varlik Selin Kale, Ulusoy Cağri

机构信息

Department of Orthodontics, Faculty of Dentistry, Gazi University, Ankara, Turkey.

出版信息

Am J Orthod Dentofacial Orthop. 2009 Feb;135(2):194-8. doi: 10.1016/j.ajodo.2007.12.024.

Abstract

INTRODUCTION

Our objective was to evaluate the effects of a highly filled light-cured sealant (HFLCS) on the shear bond strength and bond failure site of metal and ceramic brackets bonded with resin-modified glass ionomer cement (RMGIC).

METHODS

Eighty freshly extracted maxillary premolars were randomly divided into 4 groups (20 in each group). In all groups, the teeth were etched with 37% phosphoric acid for 20 seconds, and RMGIC (Fuji Ortho LC, GC Europe, Leuven, Belgium) was used for bracket bonding. In groups 1 and 3, the brackets were bonded directly to etched enamel surfaces; in groups 2 and 4, the etched enamel was covered with HFLCS (Pro Seal, Reliance Orthodontic Products, Itasca, Ill). Groups 1 and 2 received metal brackets, and groups 3 and 4 had ceramic brackets. The specimens were stored in distilled water at room temperature for 24 hours and subsequently tested in shear mode with a universal testing machine. After debonding, the teeth and the brackets were examined under a stereomicroscope (model SMZ-1B, Nikon, Osaka, Japan) at 20-times magnification to assess the residual adhesive on the tooth surfaces.

RESULTS

Interaction between HFLCS and bracket type was not statistically significant (P = 0.15). Pretreatment with HFLCS did not cause a statistically significant change in the shear bond values of either metal or ceramic brackets (P = 0.38). Shear bond values of the ceramic brackets were higher than those of the metal brackets independent of HFLCS application (P <0.001). No significant differences were found in bond failure modes in the 4 groups.

CONCLUSIONS

HFLCS application on enamel etched with 37% phosphoric acid did not affect the bond strength values and the bond failure modes of metal and ceramic brackets bonded with RMGIC.

RESULTS

Interaction between HFLCS and bracket type was not statistically significant (P = 0.15). Pretreatment with HFLCS did not cause a statistically significant change in the shear bond values of either metal or ceramic brackets (P = 0.38). Shear bond values of the ceramic brackets were higher than those of the metal brackets independent of HFLCS application (P <0.001). No significant differences were found in bond failure modes in the 4 groups.

CONCLUSIONS

HFLCS application on enamel etched with 37% phosphoric acid did not affect the bond strength values and the bond failure modes of metal and ceramic brackets bonded with RMGIC.

摘要

引言

我们的目的是评估高填料光固化封闭剂(HFLCS)对用树脂改性玻璃离子水门汀(RMGIC)粘结的金属和陶瓷托槽的剪切粘结强度及粘结失败部位的影响。

方法

80颗新鲜拔除的上颌前磨牙随机分为4组(每组20颗)。所有组中,牙齿均用37%磷酸酸蚀20秒,并用RMGIC(Fuji Ortho LC,GC Europe,鲁汶,比利时)进行托槽粘结。在第1组和第3组中,托槽直接粘结于酸蚀后的釉质表面;在第2组和第4组中,酸蚀后的釉质表面覆盖HFLCS(Pro Seal,Reliance Orthodontic Products,伊塔斯卡,伊利诺伊州)。第1组和第2组使用金属托槽,第3组和第4组使用陶瓷托槽。标本在室温下于蒸馏水中保存24小时,随后用万能试验机以剪切模式进行测试。脱粘后,在立体显微镜(SMZ - 1B型号,尼康,大阪,日本)下以20倍放大倍数检查牙齿和托槽,以评估牙齿表面的残余粘结剂。

结果

HFLCS与托槽类型之间的相互作用无统计学意义(P = 0.15)。HFLCS预处理未导致金属或陶瓷托槽的剪切粘结值发生统计学上的显著变化(P = 0.38)。无论是否应用HFLCS,陶瓷托槽的剪切粘结值均高于金属托槽(P <0.001)。4组的粘结失败模式无显著差异。

结论

在用37%磷酸酸蚀的釉质上应用HFLCS不会影响用RMGIC粘结的金属和陶瓷托槽的粘结强度值及粘结失败模式。

结果

HFLCS与托槽类型之间的相互作用无统计学意义(P = 0.15)。HFLCS预处理未导致金属或陶瓷托槽的剪切粘结值发生统计学上的显著变化(P = 0.38)。无论是否应用HFLCS,陶瓷托槽的剪切粘结值均高于金属托槽(P <0.001)。4组的粘结失败模式无显著差异。

结论

在用37%磷酸酸蚀的釉质上应用HFLCS不会影响用RMGIC粘结的金属和陶瓷托槽的粘结强度值及粘结失败模式。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验