To quantify normal neurosensory facial sensibility in a young healthy Chinese population for use as a reference when evaluating postoperative nerve damage.
One hundred consecutive eligible normal young Chinese individuals were included. Each subject underwent objective neurosensory testing (static light touch, 2-point static, and pain detection thresholds) at 8 facial sites within the distribution of the trigeminal nerve. Data were calculated into means and standard deviations, and paired t tests were used to compare values between the left and right sides and quadrants; unpaired t test was used to compare the values between genders. A P value of <or=.05 was considered to be significant.
The chin region was least sensitive to light touch detection, and the normal thresholds ranged from 1.72 to 1.80. The infraorbital areas were least sensitive for 2-point discrimination, and the normal values for this modality ranged from 7.04 mm to 11.87 mm. Infraorbital areas were also most resistant to pain, and normal values ranged from 13.17 g to 20.30 g. There was no statistically significant difference between facial sides or quadrants. Male subjects were found to have a higher pain detection threshold, especially in the chin and the right infraorbital areas.
Reference values for normal facial sensibility in the form of objective neurosensory testing scores have been documented for a healthy Chinese population. These results provide baseline data for future surgical studies in this and similar populations.
量化年轻健康中国人群正常的神经感觉性面部敏感性,以便在评估术后神经损伤时作为参考。
纳入连续100名符合条件的正常中国年轻个体。每位受试者在三叉神经分布区域内的8个面部部位接受客观神经感觉测试(静态轻触、两点静态和疼痛检测阈值)。数据计算为均值和标准差,并使用配对t检验比较左右两侧和象限之间的值;使用非配对t检验比较性别之间的值。P值≤0.05被认为具有统计学意义。
下巴区域对轻触检测最不敏感,正常阈值范围为1.72至1.80。眶下区域对两点辨别最不敏感,该模式的正常范围为7.04毫米至11.87毫米。眶下区域对疼痛也最具耐受性,正常范围为13.17克至20.30克。面部两侧或象限之间无统计学显著差异。发现男性受试者的疼痛检测阈值较高,尤其是在下巴和右侧眶下区域。
已记录了以客观神经感觉测试分数形式表示的健康中国人群正常面部敏感性的参考值。这些结果为该人群及类似人群未来的外科研究提供了基线数据。