作为原发性开角型青光眼和高眼压症的主要治疗方法,180度和360度选择性激光小梁成形术(SLT)术后随访期间眼压波动情况的比较。

A comparison of the intervisit intraocular pressure fluctuation after 180 and 360 degrees of selective laser trabeculoplasty (SLT) as a primary therapy in primary open angle glaucoma and ocular hypertension.

作者信息

Prasad Navin, Murthy Shashidhar, Dagianis John J, Latina Mark A

机构信息

Massachusetts Eye and Ear Infirmary, Boston, MA, USA.

出版信息

J Glaucoma. 2009 Feb;18(2):157-60. doi: 10.1097/IJG.0b013e3181752c97.

Abstract

OBJECTIVE

To determine and compare the effect of 180 and 360 degrees of selective laser trabeculoplasty (SLT) treatment as a primary therapy on the intervisit intraocular pressure (IOP) fluctuation in patients followed up for a period of 2 years without any further medical or surgical intervention.

METHODS

Retrospective chart review of patients with ocular hypertension and primary open angle glaucoma who received SLT as primary therapy without any subsequent medical or surgical intervention. IOP before SLT and postlaser IOP at all the visits during the follow-up period of months 6 to 24 was determined. The standard deviation (SD) of the mean IOP was used as a surrogate for IOP fluctuation.

RESULTS

Forty-one eyes were treated by SLT, 19 eyes in the 180-degree group and 22 eyes in the 360-degree group. The mean reduction in IOP at 2 years was 28% in 180-degree group and 35% in 360-degree SLT group. After the SLT, the 360-degree SLT group had a lower IOP fluctuation compared with the 180-degree SLT group over the follow-up period of months 6 to 24. The percentage of eyes with intervisit IOP fluctuation (SD) <or=2 mm Hg during the same follow-up period was significantly greater in 360-degree SLT treatment group (86%) than in the 180-degree SLT treatment group (52%), P=0.03. The odds of achieving IOP fluctuation <or=2 mm Hg were 5.7 times greater with 360 degrees than with 180-degree SLT during the follow-up period of months 6 to 24.

CONCLUSIONS

This study suggests that 360-degree SLT is more efficacious in achieving smaller IOP fluctuations than treatment with 180-degree SLT.

摘要

目的

确定并比较180度和360度选择性激光小梁成形术(SLT)作为初始治疗对随访2年且未进行任何进一步药物或手术干预的患者就诊期间眼压(IOP)波动的影响。

方法

对接受SLT作为初始治疗且未进行任何后续药物或手术干预的高眼压症和原发性开角型青光眼患者进行回顾性病历审查。确定SLT术前以及随访6至24个月期间所有就诊时的激光术后眼压。平均眼压的标准差(SD)用作眼压波动的替代指标。

结果

41只眼接受了SLT治疗,180度组19只眼,360度组22只眼。180度组2年时眼压平均降低28%,360度SLT组为35%。SLT术后,在6至24个月的随访期内,360度SLT组的眼压波动低于180度SLT组。在同一随访期内,就诊期间眼压波动(SD)≤2 mmHg的眼的百分比在360度SLT治疗组(86%)显著高于180度SLT治疗组(52%),P = 0.03。在6至24个月的随访期内,360度SLT实现眼压波动≤2 mmHg的几率是180度SLT的5.7倍。

结论

本研究表明,与180度SLT治疗相比,360度SLT在实现更小的眼压波动方面更有效。