[An experimental study on the alteration of myocardial tissue by radiofrequency catheter ablation: differences according to the frequency and the device].

作者信息

Ikeda T, Sugi K, Ninomiya K, Enjoji Y, Nishiwaki H, Abe R, Yabuki S, Machii K, Takahashi K, Naoe S

机构信息

Third Department of Internal Medicine, Toho University, School of Medicine, Ohashi Hospital.

出版信息

Kokyu To Junkan. 1991 Aug;39(8):807-11.

PMID:1925102
Abstract

To evaluate the alteration of myocardial tissue by radiofrequency (RF) catheter ablation according to differences of the frequency and the device, we applied RF catheter ablation to canine right ventricular myocardium in vitro. The devices delivering RF energy were LL-49(0. 49MHz, fixed voltage mode), RA-50 (13.56MHz, fixed watt mode) and HAT200 (0.52MHz, fixed watt mode with the capability of temperature adjustment). After RF catheter ablation were performed with a unipolar electrode catheter at various output under the same condition of contact, the ablated lesions by each device were compared. Histologically, we recognized coagulation layer with the necrosis of endocardium and the dissociation of myocardium in each experiment. The degree and the size of ablation layer was significantly larger in lower frequency delivery (p less than 0.05) and was significantly smaller by using the device with temperature adjustment as compared with the others (p less than 0.05). It was suggested that the alteration of myocardial tissue ablated with RF energy differ according to the frequency and the mode of output adjustment of the device.

摘要

相似文献

1
[An experimental study on the alteration of myocardial tissue by radiofrequency catheter ablation: differences according to the frequency and the device].
Kokyu To Junkan. 1991 Aug;39(8):807-11.
2
[Is radiofrequency catheter ablation available for treatment of ventricular tachycardias?--Effects of sequential unipolar applications using multiple electrode catheter].
Kokyu To Junkan. 1992 May;40(5):467-72.
3
[The influence of repetitive delivery of radiofrequency current in catheter ablation].
Kokyu To Junkan. 1993 Apr;41(4):383-8.
4
[An experimental study of determining the appropriate frequency of radiofrequency catheter ablation in vitro and in vivo for ventricular tachycardias].[体外及体内确定室性心动过速射频导管消融合适频率的实验研究]
Kokyu To Junkan. 1992 Oct;40(10):975-80.
5
Large radiofrequency ablation lesions can be created with a retractable infusion-needle catheter.可使用可伸缩的输液针导管创建大型射频消融病灶。
J Cardiovasc Electrophysiol. 2006 Jun;17(6):657-61. doi: 10.1111/j.1540-8167.2006.00439.x.
6
[An experimental study of catheter ablation using microwave energy via coaxial electrode catheter].
Kokyu To Junkan. 1993 Oct;41(10):981-5.
7
Dual-probe radiofrequency ablation: an in vitro experimental study in bovine liver.双探针射频消融:在牛肝脏中的体外实验研究
Invest Radiol. 2004 Feb;39(2):89-96. doi: 10.1097/01.rli.0000105041.12347.4b.
8
Transcatheter radiofrequency ablation of atrial tissue using a suction catheter.使用抽吸导管对心房组织进行经导管射频消融。
Pacing Clin Electrophysiol. 1989 Jan;12(1 Pt 2):177-86. doi: 10.1111/j.1540-8159.1989.tb02645.x.
9
Catheter ablation of ventricular epicardial tissue: a comparison of standard and cooled-tip radiofrequency energy.心室心外膜组织的导管消融:标准与冷盐水灌注射频能量的比较
Circulation. 2004 May 18;109(19):2363-9. doi: 10.1161/01.CIR.0000128039.87485.0B. Epub 2004 Apr 19.
10
Pilot clinical study of a novel minimally invasive bipolar microneedle radiofrequency device.新型微创双极微针射频设备的临床前期研究
Lasers Surg Med. 2009 Feb;41(2):87-95. doi: 10.1002/lsm.20687.