Suppr超能文献

使用光学相干断层扫描进行术前有晶状体眼人工晶状体模拟的价值。

Value of preoperative phakic intraocular lens simulation using optical coherence tomography.

作者信息

Doors Muriël, Berendschot Tos T J M, Hendrikse Fred, Webers Carroll A B, Nuijts Rudy M M A

机构信息

From the Department of Ophthalmology, Academic Hospital Maastricht, Maastricht, The Netherlands.

出版信息

J Cataract Refract Surg. 2009 Mar;35(3):438-43. doi: 10.1016/j.jcrs.2008.11.033.

Abstract

PURPOSE

To compare the position of the iris-fixated phakic intraocular lens (pIOL) in preoperative simulation and after implantation using anterior segment optical coherence tomography (AS-OCT).

SETTING

Department of Ophthalmology, Academic Hospital Maastricht, Maastricht, The Netherlands.

METHODS

In this prospective study, the morphometrics of the anterior chamber were analyzed using preoperative pIOL simulation and postoperative images assessed with AS-OCT. Patients' eyes were examined before and 6 months after pIOL implantation. The measured distances were from the center of the pIOL to the endothelium, from the edge of the pIOL to the endothelium (nasal and temporal side), and from the back of the pIOL to the crystalline lens.

RESULTS

Thirty-four eyes (18 patients) were examined. All morphometric parameters showed highly significant correlations and small mean differences between preoperative and postoperative measurements. However, the distance from the nasal edge of the pIOL to the endothelium and the distance from the pIOL to the crystalline lens showed a statistically significant difference between the preoperative simulation and the actual postoperative measurements (P = .045 and P = .001, respectively). The ranges of agreement between all preoperative simulations and postoperative measurements ranged between 0.24 mm and 0.29 mm.

CONCLUSIONS

Preoperative simulation was a useful additional tool in the selection of patients considering pIOL implantation and in ensuring the long-term safety of pIOLs. However, clinicians should be aware of the range between the preoperative simulation and the postoperative measurements.

摘要

目的

使用眼前节光学相干断层扫描(AS-OCT)比较虹膜固定型有晶状体眼人工晶状体(pIOL)在术前模拟和植入后的位置。

设置

荷兰马斯特里赫特学术医院眼科。

方法

在这项前瞻性研究中,使用术前pIOL模拟和AS-OCT评估的术后图像分析前房的形态学指标。在pIOL植入前和植入后6个月对患者的眼睛进行检查。测量的距离包括从pIOL中心到内皮、从pIOL边缘到内皮(鼻侧和颞侧)以及从pIOL后部到晶状体的距离。

结果

检查了34只眼(18例患者)。所有形态学参数在术前和术后测量之间均显示出高度显著的相关性和较小的平均差异。然而,pIOL鼻侧边缘到内皮的距离以及pIOL到晶状体的距离在术前模拟和实际术后测量之间显示出统计学上的显著差异(分别为P = 0.045和P = 0.001)。所有术前模拟和术后测量之间的一致性范围在0.24 mm至0.29 mm之间。

结论

术前模拟是选择考虑植入pIOL的患者以及确保pIOL长期安全性的有用辅助工具。然而,临床医生应了解术前模拟和术后测量之间的范围。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验