Ongkosuwito E M, Dieleman M M J, Kuijpers-Jagtman A M, Mulder P G H, van Neck J W
Erasmus MC, University Medical Center, Rotterdam, the Netherlands.
Cleft Palate Craniofac J. 2009 Mar;46(2):147-53. doi: 10.1597/07-123.1. Epub 2008 Jun 3.
To investigate the reliability of length measurements of the mandible by comparing orthopantomograms (OPTs) with lateral cephalograms.
Observational study.
OPTs and lateral cephalograms were taken of 20 human dry skulls. Four orthodontists and four maxillofacial surgeons located landmarks on all radiographs using a computer program for cephalometric measurements. Intraobserver and interobserver variability in locating landmarks was assessed, as well as positioning of the skulls prior to radiography between the x-ray assistants. Magnification differences between the left and right side of the mandible on the OPT were determined for five skulls. Kappa statistics were used to calculate the intraclass correlation coefficient for intraobserver and interobserver differences. An F test was used to assess differences between methods and between type of observer.
No significant differences were found in the magnification factor of the left and right side of the mandible. Compared with a lateral cephalogram, the OPT had comparable reliability in measuring mandibular distances condylion-gonion, gonion-menton, and condylion-menton. No significant differences were observed between the x-ray assistants in taking the OPTs and lateral cephalograms or in repositioning the skulls. Significant differences were found between orthodontists and maxillofacial surgeons for landmark measurements.
An OPT is as reliable as a lateral cephalogram for linear measurements of the mandible (condylion-gonion, gonion-menton, and condylion-menton).
通过比较曲面断层片(OPT)和头颅侧位片,研究下颌骨长度测量的可靠性。
观察性研究。
对20个人类干燥颅骨拍摄OPT和头颅侧位片。四名正畸医生和四名颌面外科医生使用计算机程序进行头影测量,在所有X光片上确定标志点。评估了标志点定位的观察者内和观察者间的变异性,以及X光助手在拍摄X光片之前颅骨的定位情况。确定了五个颅骨的OPT上下颌骨左右侧的放大差异。使用Kappa统计量计算观察者内和观察者间差异的组内相关系数。使用F检验评估方法之间以及观察者类型之间存在的差异。
下颌骨左右侧的放大倍数没有显著差异。与头颅侧位片相比,OPT在测量髁突-角点、角点-颏下点和髁突-颏下点的下颌距离方面具有相当的可靠性。X光助手在拍摄OPT和头颅侧位片或重新定位颅骨方面没有观察到显著差异。在标志点测量方面,正畸医生和颌面外科医生之间存在显著差异。
在测量下颌骨的线性距离(髁突-角点、角点-颏下点和髁突-颏下点)时,OPT与头颅侧位片一样可靠。