Ilyas Asif M, Reish Matthew W, Beg Tasnim M, Thoder Joseph J
Temple Hand Center, Department of Orthopaedic Surgery, Temple University Hospital, Philadelphia, PA 19140, USA.
Tech Hand Up Extrem Surg. 2009 Mar;13(1):30-3. doi: 10.1097/BTH.0b013e318187bb45.
Malunion of the distal radius are the most common complications of distal radius fractures. Increased angulation of the distal radius can result in altered load concentrations on the wrist, decreased range of motion, decreased grip strength, and residual incongruence of the radiocarpal and distal radioulnar joints. Multiple options exist for fixation of corrective osteotomies of the distal radius, including intramedullary nails. The use of an intramedullary nail provides the benefits of a percutaneous insertion technique, low-profile implant, load-sharing design, and fixed-angle locking screws in the distal fragment. We describe an innovative technique for intramedullary fixation for corrective osteotomies of extraarticular distal radius malunions.