Suppr超能文献

基于硫氰酸盐与2-(5-溴-2-吡啶偶氮)-5-二乙氨基苯酚及重铬酸盐反应的分光光度流动注射法测定痕量硫氰酸盐:吸烟者和非吸烟者唾液中硫氰酸盐水平的测定

Spectrophotometric flow injection determination of trace amounts of thiocyanate based on its reaction with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol and dichromate: assay of the thiocyanate level in saliva from smokers and non-smokers.

作者信息

Bendtsen A B, Hansen E H

机构信息

Chemistry Department A, Technical University of Denmark, Lyngby.

出版信息

Analyst. 1991 Jun;116(6):647-51. doi: 10.1039/an9911600647.

Abstract

A simple and very sensitive spectrophotometric flow injection (FI) procedure for the determination of trace amounts of thiocyanate is described. The proposed method is based on the reaction between thiocyanate and 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol, which, in 2 mol dm-3 acidic media in the presence of a strong oxidizing agent, produces an intensely coloured product. Several oxidants are potentially applicable, but it is shown that dichromate is preferable. As the reaction product formed is unstable and the signal inherently is recorded on a high background level, it is demonstrated that FI constitutes an ideal method in order to monitor reproducibly and repeatedly the kinetically transient signal that is obtained. Based on optimization by a factorial experimental design, the detection limit of the procedure was found to be 3.5 mumol dm-3, and the standard deviation between samples was 0.16 mumol dm-3. No significant interferences were observed; a 1000-fold excess of cyanide could readily be tolerated within the experimental error. With a sample volume of 50 microliters being injected, the sampling frequency was 60 samples h-1. The system was tested with saliva samples from non-smokers and smokers, and the results show that it is possible to distinguish between these two categories of individuals. As an added benefit, the detection limit of the analytical procedure allows the samples to be diluted 100-fold, so that centrifugation for 5 min is the only preliminary sample preparation that is necessary.

摘要

描述了一种用于测定痕量硫氰酸盐的简单且非常灵敏的分光光度流动注射(FI)方法。所提出的方法基于硫氰酸盐与2-(5-溴-2-吡啶偶氮)-5-二乙氨基苯酚之间的反应,在2 mol dm⁻³酸性介质中,在强氧化剂存在下,该反应会产生颜色很深的产物。有几种氧化剂可能适用,但结果表明重铬酸盐是更合适的。由于形成的反应产物不稳定且信号本身是在高背景水平上记录的,因此证明FI是一种理想的方法,可用于可重复且反复地监测所获得的动力学瞬态信号。基于析因实验设计进行优化后,该方法的检测限为3.5 μmol dm⁻³,样品间的标准偏差为0.16 μmol dm⁻³。未观察到明显干扰;在实验误差范围内,氰化物1000倍的过量很容易被容忍。进样体积为50微升时,采样频率为每小时60个样品。该系统用非吸烟者和吸烟者的唾液样本进行了测试,结果表明可以区分这两类个体。另外,该分析方法的检测限允许将样品稀释100倍,因此仅需5分钟的离心作为唯一必要的样品预处理。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验