Holanda Marcelo Alcantara, Reis Ricardo Coelho, Winkeler Georgia Freire Paiva, Fortaleza Simone Castelo Branco, Lima José Wellington de Oliveira, Pereira Eanes Delgado Barros
Department of Clinical Medicine, School of Medicine, Federal University of Ceará, Fortaleza, Brazil.
J Bras Pneumol. 2009 Feb;35(2):164-73. doi: 10.1590/s1806-37132009000200010.
Failure of noninvasive ventilation (NIV) has been associated with short-term adverse effects related to the use of masks. The aim of this study was to compare the incidence, type and intensity of adverse effects, as well as the comfort, of total face masks (TFMs), facial masks (FMs) and nasal masks (NMs) during NIV.
This was a randomized crossover trial involving 24 healthy volunteers submitted to six sessions of NIV in bilevel positive airway pressure mode using the TFM, FM and NM masks at low and moderate-to-high pressure levels. A written questionnaire was applied in order to evaluate eleven specific adverse effects related to the use of the masks. Comfort was assessed using a visual analog scale. The CO2 exhaled into the ventilator circuit was measured between the mask and the exhalation port.
The performance of the TFM was similar to that of the NM and FM in terms of comfort scores. Higher pressure levels reduced comfort and increased adverse effects, regardless of the mask type. When the TFM was used, there were fewer air leaks and less pain at the nose bridge, although there was greater oronasal dryness and claustrophobia. Air leaks were most pronounced when the FM was used. The partial pressure of exhaled CO2 entering the ventilator circuit was zero for the TFM.
The short-term adverse effects caused by NIV interfaces are related to mask type and pressure settings. The TFM is a reliable alternative to the NM and FM. Rebreathing of CO2 from the circuit is less likely to occur when a TFM is used.
无创通气(NIV)失败与使用面罩相关的短期不良反应有关。本研究的目的是比较在NIV期间全面罩(TFM)、面部面罩(FM)和鼻罩(NM)的不良反应发生率、类型和强度,以及舒适度。
这是一项随机交叉试验,纳入24名健康志愿者,以双水平气道正压模式使用TFM、FM和NM面罩在低压力水平和中高压力水平下进行6次NIV。应用书面问卷来评估与使用面罩相关的11种特定不良反应。使用视觉模拟量表评估舒适度。在面罩和呼气端口之间测量呼出到通气回路中的二氧化碳。
就舒适度评分而言,TFM的表现与NM和FM相似。无论面罩类型如何,较高的压力水平都会降低舒适度并增加不良反应。使用TFM时,漏气较少,鼻梁处疼痛较轻,尽管口鼻干燥和幽闭恐惧症更严重。使用FM时漏气最明显。TFM进入通气回路的呼出二氧化碳分压为零。
NIV接口引起的短期不良反应与面罩类型和压力设置有关。TFM是NM和FM的可靠替代品。使用TFM时,回路中二氧化碳再呼吸的可能性较小。