Suppr超能文献

骨水泥型双极髋关节假体的拆卸

Disassembly of cemented bipolar prothesis of the hip.

作者信息

Guo Jiong Jiong, Yang Huilin, Yang Tongqi, Tang Tiansi

机构信息

Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou 215006, China.

出版信息

Orthopedics. 2008 Aug;31(8):813.

Abstract

A case of spontaneous disassembly of a bipolar prothesis after hemiarthroplasty due to a dislocation of the hip in an 85-year-old woman is presented, which is a rare complication. Open reduction was performed and original components were used because there was no acetabular and polyethylene linear erosion. The result was satisfactory at final follow-up (36 months), and radiographs showed no acetabular erosion, polyethylene wear, femoral subsidence, or component migration. To date, only 6 cases of disassembly of bipolar components have been reported in the English literature. In almost all cases, the injury was caused without any significant force, as only 2 patients reported a fall. Most were elderly women. We classified them into 3 types according to the etiology: iatrogenic disassembly (type I), erosion of the polyethylene liner (type II), and spontaneous disassembly (type III). Spontaneous disassembly is uncommon and seemed to be caused by a failure of the locking mechanism between the head components, resulting in an intraacetabular dislocation. Open reduction is required and revision surgery is judged by the locking mechanism between components. When there is no acetabular and polyethylene linear erosion, we believe that the original components can be used again. Although the potential disadvantage of bipolar systems shown here does not outweigh the advantages, we should rethink the status of bipolar hemiarthroplasty.

摘要

本文报告了一例85岁女性因髋关节脱位行半关节置换术后双极假体自发解体的病例,这是一种罕见的并发症。由于没有髋臼和聚乙烯线性磨损,进行了切开复位并使用了原组件。末次随访(36个月)结果满意,X线片显示无髋臼磨损、聚乙烯磨损、股骨下沉或组件移位。迄今为止,英文文献中仅报道了6例双极组件解体的病例。几乎在所有病例中,损伤都是在没有任何显著外力的情况下发生的,因为只有2例患者报告有跌倒。大多数是老年女性。我们根据病因将其分为3种类型:医源性解体(I型)、聚乙烯衬垫磨损(II型)和自发解体(III型)。自发解体并不常见,似乎是由头部组件之间的锁定机制故障导致髋臼内脱位引起的。需要切开复位,手术翻修需根据组件之间的锁定机制来判断。当没有髋臼和聚乙烯线性磨损时,我们认为可以再次使用原组件。尽管此处显示的双极系统的潜在缺点并不超过其优点,但我们应该重新审视双极半关节置换术的地位。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验