Suppr超能文献

[经食管多普勒超声心动图对冠状动脉的成像及冠状动脉血流测量:与经胸多普勒超声心动图的比较]

[Imaging of coronary arteries and measurement of coronary flow using transesophageal Doppler echocardiography: a comparison with transthoracic Doppler echocardiography].

作者信息

Hirabayashi K, Morita H, Mizushige K, Yamada S, Ohmori K, Tanimoto T, Matsuo H

机构信息

Second Department of Internal Medicine, Kagawa Medical School.

出版信息

J Cardiol Suppl. 1991;26:15-24.

PMID:1930887
Abstract

Recent advances in Doppler echocardiographic techniques, especially using transesophageal approach, enable us to observe coronary arteries and their blood flow. However, the advantages of transesophageal approach in the evaluation of coronary artery are indistinct. The aim of this study was to examine the ability of transesophageal Doppler echocardiography (TED) and transthoracic Doppler echocardiography (TTD) to visualize coronary artery and measure its flow. The study population consisted of 17 healthy subjects and 41 patients with heart diseases (arrhythmia in 2, valvular disease in 10, ischemic heart disease without complete or subtotal obstruction of coronary artery in 22, congenital heart disease in two, cardiomyopathy in four, and infective endocarditis in one). Thirty subjects were examined by TED, and 44 subjects were examined by TTD. Two patients with complete obstruction of the proximal right coronary artery (RCA), who were not included in the above-mentioned subjects, were examined by TED. The results were as follows: 1) The detection rate of coronary arteries by TED and TTD were: left main trunk (LMT); 96.7/86.4%, left anterior descending artery (LAD) and left circumflex artery (LCx); 83.3/56.8%, and RCA; 63.3/38.6%, respectively. 2) Visible length from the orifice: LMT to LAD; 22.2/30.8 mm, RCA; 20.4/22.3 mm. 3) The detection rate of coronary flow by pulsed Doppler of the two methods: LMT; 66.8/0%, LAD; 70.0/31.8%, LCx; 6.6/0%. RCA; 26.7/0%. 4) Coronary flow was detected by transesophageal two-dimensional Doppler in 73.3% of LMT, 76.6% of LAD, 6.6% LCx and 43.3% of RCA. 5) RCA flow was not detected by transesophageal two-dimensional Doppler in two patients who had complete obstruction of the proximal RCA although RCA near the orifice was obviously imaged by two-dimensional echocardiography. In conclusion, TED had an advantage over TTD in detecting coronary arteries and their blood flow, but TTD had an advantage over TED as to the visible length of coronary artery. When RCA near the orifice was clearly visualized, the absence of RCA flow by TED implied complete obstruction of the proximal RCA.

摘要

多普勒超声心动图技术的最新进展,尤其是经食管途径的应用,使我们能够观察冠状动脉及其血流情况。然而,经食管途径在评估冠状动脉方面的优势并不明显。本研究旨在探讨经食管多普勒超声心动图(TED)和经胸多普勒超声心动图(TTD)观察冠状动脉及其测量血流的能力。研究对象包括17名健康受试者和41例心脏病患者(2例心律失常、10例瓣膜病、22例无冠状动脉完全或次全阻塞的缺血性心脏病、2例先天性心脏病、4例心肌病、1例感染性心内膜炎)。30名受试者接受了TED检查,44名受试者接受了TTD检查。另外两名右冠状动脉近端完全阻塞的患者(未纳入上述研究对象)接受了TED检查。结果如下:1)TED和TTD对冠状动脉的检出率分别为:左主干(LMT)96.7%/86.4%,左前降支(LAD)和左旋支(LCx)83.3%/56.8%,右冠状动脉(RCA)63.3%/38.6%。2)从开口处可见的长度:LMT至LAD为22.2/30.8mm,RCA为20.4/22.3mm。3)两种方法的脉冲多普勒对冠状动脉血流的检出率:LMT为66.8%/0%,LAD为70.0%/31.8%,LCx为6.6%/0%,RCA为26.7%/0%。4)经食管二维多普勒在73.3%的LMT、76.6%的LAD、6.6%的LCx和43.3%的RCA中检测到冠状动脉血流。5)在两名右冠状动脉近端完全阻塞的患者中,尽管二维超声心动图可清晰显示开口附近的RCA,但经食管二维多普勒未检测到RCA血流。总之,TED在检测冠状动脉及其血流方面优于TTD,但TTD在冠状动脉可见长度方面优于TED。当开口附近的RCA清晰可见时,TED未检测到RCA血流提示右冠状动脉近端完全阻塞。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验