Department of Ophthalmology, Hamilton Glaucoma Center, University of California, San Diego, La Jolla, CA 92037-0946, USA.
J Glaucoma. 2010 Feb;19(2):77-82. doi: 10.1097/IJG.0b013e31819f934e.
To evaluate the effect of operator and optical defocus on the variability of pattern electroretinogram optimized for glaucoma detection (PERGLA).
Two different operators obtained 2 PERGLA recordings each from 10 healthy participants (5 women, mean age 32.1+/-10.3 y). In addition, one of the operators obtained recordings in which corrective lenses of various diopters (+/-0.5, +/-1, +/-2, and +/-3) were used to generate optical defocus in both eyes. The effect of operator on PERGLA amplitude and phase variability was determined using a single nested variance components' analysis model and by using Bland-Altman plots. One-way analysis of variance (ANOVA) was used to determine the effect of optical defocus on amplitude and phase.
Differences in measurements between operators accounted for approximately 26.6% and 18.2% of the total variance for amplitude and phase, respectively. Results were confirmed by the use of Bland-Altman plots. ANOVA identified a significant effect of defocus on mean amplitude (F=2.65, P=0.01), but not phase (F=1.02, P=0.42).
Measurements obtained by different operators can result in significant differences in PERGLA amplitude. In addition, although optical defocus leads to a decrease in PERGLA amplitude by reducing visual acuity, this can be avoided by obtaining J1 or better vision before testing.
评估操作者和光学离焦对青光眼检测优化图形视网膜电图(PERGLA)变异性的影响。
两名不同的操作者分别对 10 名健康参与者(5 名女性,平均年龄 32.1+/-10.3 岁)进行了 2 次 PERGLA 记录。此外,其中一名操作者使用各种屈光度(+/-0.5、+/-1、+/-2 和+/-3)的矫正镜片在双眼产生光学离焦,从而获得记录。使用单嵌套方差分量分析模型和 Bland-Altman 图确定操作者对 PERGLA 幅度和相位变异性的影响。使用单因素方差分析(ANOVA)确定光学离焦对幅度和相位的影响。
操作者之间的测量差异分别占幅度和相位总方差的约 26.6%和 18.2%。Bland-Altman 图也证实了这一结果。ANOVA 确定了离焦对平均幅度(F=2.65,P=0.01)有显著影响,但对相位(F=1.02,P=0.42)没有影响。
不同操作者获得的测量结果可能导致 PERGLA 幅度的显著差异。此外,尽管光学离焦通过降低视力导致 PERGLA 幅度下降,但可以通过在测试前获得 J1 或更好的视力来避免这种情况。