Suppr超能文献

非体外循环冠状动脉搭桥术后使用无钳手工缝合近端吻合装置的大隐静脉移植物的中期通畅率

Intermediate-term patency of saphenous vein graft with a clampless hand-sewn proximal anastomosis device after off-pump coronary bypass grafting.

作者信息

Shimokawa Tomoki, Manabe Susumu, Sawada Takahiro, Matsuyama Shigefumi, Fukui Toshihiro, Takanashi Shuichiro

机构信息

Department of Cardiovascular Surgery, Sakakibara Heart Institute, Tokyo, Japan.

出版信息

Ann Thorac Surg. 2009 May;87(5):1416-20. doi: 10.1016/j.athoracsur.2009.02.090.

Abstract

BACKGROUND

To avoid complications related to aortic manipulation, devices were developed to perform clampless anastomosis. However, there are few studies concerning the late patency of the graft. The aims of this study were to investigate the patency rate of saphenous vein (SV) graft after off-pump coronary artery bypass grafting (OPCAB) and to evaluate the influence of a clampless hand-sewn proximal anastomosis on late graft patency.

METHODS

Patients (n = 232) were enrolled who underwent OPCAB with SV grafts from 2004 to 2007 and had follow-up angiography. For proximal anastomoses, a clampless device was used in 73 (group A; HEARTSTRING [Guidant Corporation, Santa Clara, CA] in 54, Enclose II [Novare Surgical Systems, Inc, Cupertino, CA] in 19), and partial clamping was used in 159 (group B). The proximal anastomosis procedure was modified according to the results of epiaortic ultrasonography. Coronary angiography was performed early (11.8 +/- 10.4 days) and one-year postoperatively (n = 180, 371.5 +/- 102.6 days).

RESULTS

There were no significant differences in patient characteristics between the two groups except for a higher reoperation rate in group A. The overall SV patency rate at the early and one-year postoperative angiography was 95.7% and 83.0%, respectively. The patency rates were similar between the two groups (early: 97.3% vs 98.1%, p = 0.729; 1 year: 87.0% vs 81.3%, p = 0.316). There was also no significant difference in the target vessel revascularization rate during follow-up (6.8% vs 10.1%, p = 0.623).

CONCLUSIONS

Intermediate-term angiographic follow-up demonstrate an acceptable SV patency rate after OPCAB. The SV patency rate with a clampless device for proximal anastomosis is comparable with that with partial clamping during the first postoperative year.

摘要

背景

为避免与主动脉操作相关的并发症,已开发出用于进行无钳吻合的装置。然而,关于移植物远期通畅性的研究较少。本研究的目的是调查非体外循环冠状动脉搭桥术(OPCAB)后大隐静脉(SV)移植物的通畅率,并评估无钳手工缝合近端吻合术对移植物远期通畅性的影响。

方法

纳入2004年至2007年接受OPCAB并使用SV移植物且进行了随访血管造影的患者(n = 232)。对于近端吻合,73例使用无钳装置(A组;54例使用HEARTSTRING[Guidant公司,加利福尼亚州圣克拉拉],19例使用Enclose II[Novare外科系统公司,加利福尼亚州库比蒂诺]),159例使用部分钳夹(B组)。根据主动脉超声检查结果对近端吻合手术进行改良。术后早期(11.8±10.4天)和术后一年(n = 180,371.5±102.6天)进行冠状动脉造影。

结果

除A组再次手术率较高外,两组患者特征无显著差异。术后早期和术后一年血管造影时总的SV通畅率分别为95.7%和83.0%。两组通畅率相似(早期:97.3%对98.1%,p = 0.729;1年:87.0%对81.3%,p = 0.316)。随访期间目标血管再血管化率也无显著差异(6.8%对10.1%,p = 0.623)。

结论

中期血管造影随访显示OPCAB后SV通畅率可接受。术后第一年,使用无钳装置进行近端吻合的SV通畅率与部分钳夹相当。