Suppr超能文献

前列腺的机器人图像引导针干预。

Robotic image-guided needle interventions of the prostate.

作者信息

Mozer Pierre C, Partin Alan W, Stoianovici Dan

机构信息

James Buchanan Brady Urological Institute, Johns Hopkins Medicine Baltimore, MD.

出版信息

Rev Urol. 2009 Winter;11(1):7-15.

Abstract

Prostate biopsy and needle-directed prostate therapies are currently performed free-handed or with needle external templates under ultrasound guidance. Direct image-guided intervention robots are modern instruments that have the potential to substantially enhance these procedures. These may increase the accuracy and repeatability with which needles are placed in the gland. The authors' group has developed a robot for precise prostate targeting that operates remotely alongside the patient in the magnetic resonance imaging scanner, as guided according to the image.

摘要

目前,前列腺活检和针引导前列腺治疗是在超声引导下徒手进行或使用针外模板进行的。直接图像引导介入机器人是现代仪器,有可能显著改进这些操作。这可能会提高将针插入腺体的准确性和可重复性。作者团队开发了一种用于精确前列腺靶向的机器人,该机器人在磁共振成像扫描仪中与患者并行远程操作,并根据图像进行引导。

相似文献

2
An ultra-high field strength MR image-guided robotic needle delivery system for in-bore small animal interventions.
Med Phys. 2017 Nov;44(11):5544-5555. doi: 10.1002/mp.12534. Epub 2017 Sep 30.
3
MRI-safe robot for targeted transrectal prostate biopsy: animal experiments.
BJU Int. 2014 Jun;113(6):977-85. doi: 10.1111/bju.12335. Epub 2013 Dec 2.
4
Image-guided prostate biopsy robots: A review.
Math Biosci Eng. 2023 Jul 17;20(8):15135-15166. doi: 10.3934/mbe.2023678.
5
Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.
IEEE Trans Biomed Eng. 2013 Jun;60(6):1728-34. doi: 10.1109/TBME.2013.2241430. Epub 2013 Jan 21.
6
Advancements in magnetic resonance-guided robotic interventions in the prostate.
Top Magn Reson Imaging. 2008 Dec;19(6):297-304. doi: 10.1097/RMR.0b013e3181aa68b8.
7
"MRI Stealth" robot for prostate interventions.
Minim Invasive Ther Allied Technol. 2007;16(4):241-8. doi: 10.1080/13645700701520735.
8
Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention.
IEEE ASME Trans Mechatron. 2012 Sep 12;18(1):273-284. doi: 10.1109/TMECH.2011.2163523. Epub 2011 Oct 17.
9
Design of a Teleoperated Needle Steering System for MRI-guided Prostate Interventions.
Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron. 2012 Dec 31;2012:793-798. doi: 10.1109/BioRob.2012.6290862.
10
Development and preliminary evaluation of a motorized needle guide template for MRI-guided targeted prostate biopsy.
IEEE Trans Biomed Eng. 2013 Nov;60(11):3019-27. doi: 10.1109/TBME.2013.2240301. Epub 2013 Jan 15.

引用本文的文献

1
Multi-Bevel Needle Design Enabling Accurate Insertion in Biopsy for Cancer Diagnosis.
IEEE Trans Biomed Eng. 2021 May;68(5):1477-1486. doi: 10.1109/TBME.2021.3054922. Epub 2021 Apr 22.
2
Needle deflection and tissue sampling length in needle biopsy.
J Mech Behav Biomed Mater. 2020 Apr;104:103632. doi: 10.1016/j.jmbbm.2020.103632. Epub 2020 Jan 11.
3
A study on observed ultrasonic motor-induced magnetic resonance imaging (MRI) artifacts.
Biomed J. 2019 Apr;42(2):116-123. doi: 10.1016/j.bj.2018.12.007. Epub 2019 May 6.
4
Development of a shoulder-mounted robot for MRI-guided needle placement: phantom study.
Int J Comput Assist Radiol Surg. 2018 Nov;13(11):1829-1841. doi: 10.1007/s11548-018-1839-y. Epub 2018 Aug 11.
5
MRI Robots for Needle-Based Interventions: Systems and Technology.
Ann Biomed Eng. 2018 Oct;46(10):1479-1497. doi: 10.1007/s10439-018-2075-x. Epub 2018 Jun 19.
6
The Current State of MR Imaging-targeted Biopsy Techniques for Detection of Prostate Cancer.
Radiology. 2017 Nov;285(2):343-356. doi: 10.1148/radiol.2017161684.
7
MR Safe Robot, FDA Clearance, Safety and Feasibility Prostate Biopsy Clinical Trial.
IEEE ASME Trans Mechatron. 2017 Feb;22(1):115-126. doi: 10.1109/TMECH.2016.2618362. Epub 2016 Oct 20.
8
Multi-Imager Compatible, MR Safe, Remote Center of Motion Needle-Guide Robot.
IEEE Trans Biomed Eng. 2018 Jan;65(1):165-177. doi: 10.1109/TBME.2017.2697766. Epub 2017 Apr 25.
9
Development and Phantom Validation of a 3-D-Ultrasound-Guided System for Targeting MRI-Visible Lesions During Transrectal Prostate Biopsy.
IEEE Trans Biomed Eng. 2017 Apr;64(4):946-958. doi: 10.1109/TBME.2016.2582734. Epub 2016 Jun 21.
10
Design of an Optically Controlled MR-Compatible Active Needle.
IEEE Trans Robot. 2015 Feb;31(1):1-11. doi: 10.1109/TRO.2014.2367351.

本文引用的文献

1
A New Type of Motor: Pneumatic Step Motor.
IEEE ASME Trans Mechatron. 2007 Feb 1;12(1):98-106. doi: 10.1109/TMECH.2006.886258.
2
Closed-loop control in fused MR-TRUS image-guided prostate biopsy.
Med Image Comput Comput Assist Interv. 2007;10(Pt 1):128-35. doi: 10.1007/978-3-540-75757-3_16.
3
Towards 3D ultrasound image based soft tissue tracking: a transrectal ultrasound prostate image alignment system.
Med Image Comput Comput Assist Interv. 2007;10(Pt 2):26-33. doi: 10.1007/978-3-540-75759-7_4.
4
Multi-channel robotic system for prostate brachytherapy.
Annu Int Conf IEEE Eng Med Biol Soc. 2007;2007:1233-6. doi: 10.1109/IEMBS.2007.4352520.
5
Will focal therapy become a standard of care for men with localized prostate cancer?
Nat Clin Pract Oncol. 2007 Nov;4(11):632-42. doi: 10.1038/ncponc0959.
6
Focal therapy for localized prostate cancer: a critical appraisal of rationale and modalities.
J Urol. 2007 Dec;178(6):2260-7. doi: 10.1016/j.juro.2007.08.072. Epub 2007 Oct 15.
9
"MRI Stealth" robot for prostate interventions.
Minim Invasive Ther Allied Technol. 2007;16(4):241-8. doi: 10.1080/13645700701520735.
10
MR-guided interventions of the prostate gland.
Minim Invasive Ther Allied Technol. 2007;16(4):222-9. doi: 10.1080/13645700701520669.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验