Suppr超能文献

非球面双焦点人工晶状体植入后的视觉功能

Visual function after implantation of an aspheric bifocal intraocular lens.

作者信息

Alfonso José F, Fernández-Vega Luis, Amhaz Hussein, Montés-Micó Robert, Valcárcel Beatriz, Ferrer-Blasco Teresa

机构信息

Fernández-Vega Ophthalmological Institute, Surgery Department, School of Medicine, University of Oviedo, Oviedo, Spain.

出版信息

J Cataract Refract Surg. 2009 May;35(5):885-92. doi: 10.1016/j.jcrs.2009.01.014.

Abstract

PURPOSE

To evaluate distance, intermediate, and near vision after bifocal aspheric AcrySof ReSTOR SN6AD1 intraocular lens (IOL) implantation.

SETTING

Fernández-Vega Ophthalmological Institute, Oviedo, Spain.

METHODS

Binocular distance best corrected visual acuity (BCVA) (4.0 m), best distance-corrected near (40.0 cm) and intermediate (70.0, 60.0, 50.0 cm) acuities, and contrast sensitivity under photopic (85.0 candelas [cd]/m(2)) and mesopic (3.0 cd/m(2)) conditions with and without glare were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered.

RESULTS

Six months postoperatively, the mean acuities (logMAR) were binocular BCVA, -0.064 +/- 0.049 (SD); best corrected near, -0.041 +/- 0.061; best corrected intermediate, 0.147 +/- 0.130 (70.0 cm), 0.036 +/- 0.133 (60.0 cm), and -0.126 +/- 0.077 (50.0 cm). The BCVA and best corrected near acuity were 20/25 or better in all patients. Through-focus binocular logMAR acuities had 2 peaks at the expected far focus and near focus (0.00 diopter [D] and -2.40 D, respectively), with somewhat reduced acuity (20/32) at intermediate distances. Photopic contrast sensitivity was within the standard normal range. Mesopic contrast sensitivity was lower than under photopic conditions, particularly at higher spatial frequencies. Patients reported good performance for distance, near, and intermediate visual tasks with no or minimal difficulty with specific tasks. No patient reported severe visual phenomena; halos and glare were rated as none to moderate.

CONCLUSIONS

The aspheric IOL provided good functional vision at far and near, with lower performance at intermediate distance; good photopic contrast sensitivity and lower mesopic performance; and a low incidence of visual disturbances.

摘要

目的

评估双焦点非球面AcrySof ReSTOR SN6AD1人工晶状体(IOL)植入术后的远、中、近视力。

地点

西班牙奥维耶多的费尔南德斯 - 维加眼科研究所。

方法

术后测量双眼远视力最佳矫正视力(BCVA)(4.0米)、最佳矫正近视力(40.0厘米)以及中视力(70.0、60.0、50.0厘米),并在有和无眩光的明视(85.0坎德拉[cd]/平方米)和暗视(3.0 cd/平方米)条件下测量对比敏感度。发放患者满意度和视觉现象调查问卷。

结果

术后6个月,平均视力(logMAR)为双眼BCVA,-0.064±0.049(标准差);最佳矫正近视力,-0.041±0.061;最佳矫正中视力,0.147±0.130(70.0厘米),0.036±0.133(60.0厘米),以及-0.126±0.077(50.0厘米)。所有患者的BCVA和最佳矫正近视力均为20/25或更好。通过焦点的双眼logMAR视力在预期的远焦点和近焦点(分别为0.00屈光度[D]和-2.40 D)处有两个峰值,中距离处视力有所降低(20/32)。明视对比敏感度在标准正常范围内。暗视对比敏感度低于明视条件下,尤其是在较高空间频率时。患者报告在远、近和中距离视觉任务中表现良好,特定任务无困难或困难最小。没有患者报告严重的视觉现象;光晕和眩光被评为无至中度。

结论

非球面IOL在远、近视力方面提供了良好的功能性视力,中距离视力较低;明视对比敏感度良好,暗视表现较低;视觉干扰发生率低。