Alaidan Alwaleed, Bohol Marie Fe, Al-Thawadi Sahar I, Al-Suwaine Abdulrahman, Al-Qahtani Ahmed A, Al-Ahdal Mohammed N
Department of Biological and Medical Research, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.
J Microbiol Methods. 2009 Aug;78(2):238-41. doi: 10.1016/j.mimet.2009.05.007. Epub 2009 May 13.
We modified the conventional PFGE procedure for Serratia marcescens to establish a rapid method. Our protocol showed modification in the bacterial lysis, washing, and restriction enzyme digestion time. This resulted in shortening the time needed by about 3 days compared to the conventional PFGE method.