Sun Yinshi, Liu Zhengbo, Wang Jianhua, Wang Ying, Zhou Hongying, Zhang Wenli, Wang Jun, Qiao Gui
College of Agronomy, Shandong Agricultural University, Taian 271018, China.
Se Pu. 2009 Jan;27(1):114-6.
A high performance liquid chromatographic (HPLC) method was developed for the determination of four acetophenones, namely 4-hydroxyacetophenone (I), 2,5-dihydroxyacetophenone (II), baishouwubenzophenone (III) and 2,4-dihydroxyacetophenone (IV), in Radix Cynanchi bungei. The HPLC with photodiode array (PDA) detection was carried out on a Symmetry-C18 (4.6 mm x 250 mm, 5 microm) column with CH3OH-H2O (26 : 74, v/v) as the mobile phase at the flow rate of 1.0 mL/min and 30 degrees C. The compounds I , III, IV were monitored at 280 nm, and the compound II was at 224 nm. Four acetophenones (I - IV) had good linearities (r = 0.999 6 - 0.999 9) at the ranges of 0.080 - 0.560 microg, 0.080 -0.560 microg, 0.100 - 0.700 microg and 0.092 -0.644 microg, respectively. The average recoveries were from 98.0% to 104.0% with relative standard deviations (RSD) ranging from 0.8% to 2.6%. The method is of quick, simple and accurate. The method can be used for the quality control of this product.
建立了一种高效液相色谱(HPLC)法,用于测定白首乌中4-羟基苯乙酮(I)、2,5-二羟基苯乙酮(II)、白首乌二苯酮(III)和2,4-二羟基苯乙酮(IV)这4种苯乙酮类成分。采用配有光电二极管阵列(PDA)检测器的HPLC,在Symmetry-C18(4.6 mm×250 mm,5μm)色谱柱上进行分析,以甲醇-水(26∶74,v/v)为流动相,流速为1.0 mL/min,柱温为30℃。化合物I、III、IV在280 nm波长处进行监测,化合物II在224 nm波长处进行监测。4种苯乙酮类成分(I - IV)在0.080 - 0.560μg、0.080 - 0.560μg、0.100 - 0.700μg和0.092 - 0.644μg范围内均具有良好的线性关系(r = 0.999 6 - 0.999 9)。平均回收率为98.0%至104.0%,相对标准偏差(RSD)为0.8%至2.6%。该方法快速、简便、准确,可用于该产品的质量控制。