Grayev Allison, Shimakawa Ann, Cousins Joseph, Turski Patrick, Brittain Jean, Reeder Scott
University of Wisconsin, Department of Radiology, Madison, Wisconsin, USA.
J Magn Reson Imaging. 2009 Jun;29(6):1367-74. doi: 10.1002/jmri.21780.
To implement IDEAL (iterative decomposition of water and fat using echo asymmetry and least squares estimation) water-fat separation with 3D time-of-flight (TOF) magnetic resonance angiography (MRA) of intracranial vessels for improved background suppression by providing uniform and robust separation of fat signal that appears bright on conventional TOF-MRA.
IDEAL TOF-MRA and conventional TOF-MRA were performed in volunteers and patients undergoing routine brain MRI/MRA on a 3T magnet. Images were reviewed by two radiologists and graded based on vessel visibility and image quality.
IDEAL TOF-MRA demonstrated statistically significant improvement in vessel visibility when compared to conventional TOF-MRA in both volunteer and clinical patients using an image quality grading system. Overall image quality was 3.87 (out of 4) for IDEAL versus 3.55 for conventional TOF imaging (P = 0.02). Visualization of the ophthalmic artery was 3.53 for IDEAL versus 1.97 for conventional TOF imaging (P < 0.00005) and visualization of the superficial temporal artery was 3.92 for IDEAL imaging versus 1.97 for conventional TOF imaging (P < 0.00005).
By providing uniform suppression of fat, IDEAL TOF-MRA provides improved background suppression with improved image quality when compared to conventional TOF-MRA methods.
利用颅内血管的三维时间飞跃(TOF)磁共振血管造影(MRA)实现IDEAL(利用回波不对称性和最小二乘法估计对水和脂肪进行迭代分解)水脂分离,通过对传统TOF-MRA上显示为高信号的脂肪信号进行均匀且稳定的分离,以改善背景抑制效果。
对在3T磁共振成像仪上接受常规脑部MRI/MRA检查的志愿者和患者进行IDEAL TOF-MRA和传统TOF-MRA检查。由两名放射科医生对图像进行评估,并根据血管显示情况和图像质量进行分级。
在使用图像质量分级系统的情况下,与传统TOF-MRA相比,IDEAL TOF-MRA在志愿者和临床患者中均显示出血管显示情况有统计学意义的改善。IDEAL的整体图像质量评分为3.87(满分4分),而传统TOF成像为3.55(P = 0.02)。IDEAL对眼动脉的显示评分为3.53,而传统TOF成像为1.97(P < 0.00005);IDEAL对颞浅动脉的显示评分为3.92,而传统TOF成像为1.97(P < 0.00005)。
与传统TOF-MRA方法相比,IDEAL TOF-MRA通过对脂肪进行均匀抑制,改善了背景抑制效果并提高了图像质量。