Suppr超能文献

用于血液透析的右股动脉至左股静脉聚四氟乙烯移植物植入术后的高输出量心力衰竭:一例报告

High-output cardiac failure following insertion of right femoral artery to left femoral vein PTFE graft for haemodialysis: a case report.

作者信息

Acharya Sanjukta, Banerjee Debasish, Fronek Jiri, Fossati Nicoletta, Chemla Eric S

机构信息

Renal and Transplantation Unit, St George's Hospital NHS Trust, Tooting, London, United Kingdom.

出版信息

Semin Dial. 2009 Jul-Aug;22(4):462-4. doi: 10.1111/j.1525-139X.2009.00612.x. Epub 2009 May 15.

Abstract

Arteriovenous grafts used for hemodialysis can produce high-output cardiac failure as a result of shunting of blood through the dialysis access. The following case demonstrates that the problem can occur shortly after graft formation and improved with graft ligation. It caused haemodynamic compromise because of previously undiagnosed, underlying valvular heart disease. It also caused a diagnostic difficulty in the immediate postoperative period as it was mistaken for postsurgical hemorrhage.

摘要

用于血液透析的动静脉移植物可因血液通过透析通路分流而导致高输出量心力衰竭。以下病例表明,该问题可在移植物形成后不久出现,并通过结扎移植物得到改善。由于先前未被诊断出的潜在瓣膜性心脏病,它导致了血流动力学损害。它还在术后即刻造成了诊断困难,因为它被误诊为术后出血。