Suppr超能文献

患者头部位置对全景X线摄影中测量的牙齿轴向倾斜度的影响。

Influence of patient head positioning on measured axial tooth inclination in panoramic radiography.

作者信息

Hardy Timothy C, Suri Lokesh, Stark Paul

机构信息

Tufts University School of Dental Medicine, 1 Kneeland Street, Boston, MA 02111, USA.

出版信息

J Orthod. 2009 Jun;36(2):103-10. doi: 10.1179/14653120723013.

Abstract

OBJECTIVE

Panoramic radiographs are routinely used to assess the mesiodistal axial inclination of teeth (MDAI) in orthodontic treatment. These radiographs are sensitive to minor deviations from standard head position that result in image distortions. The aim of this study is to measure and quantify the changes in MDAI on panoramic radiograph resulting from changes in patient head position.

MATERIALS AND METHODS

The testing devise was a human skull with guide wires placed on the facial surface of the teeth and alveolar process along the long axis of each tooth. Panoramic radiographs were captured digitally with the orientation of the skull in Frankfurt horizontal plane parallel to the floor and with 1 degrees , 2 degrees , 5 degrees , 7 degrees , and 10 degrees both superior and inferior rotations. The mesiodistal tooth angulations were determined using MIPAC software (DentalEye and LEAD Technologies, Inc. 2005).

RESULTS

The more distal the position of the tooth in the arch the greater the change in MDAI with a change in vertical head position. A maximum change of approximately 10 degrees was observed in MDAI of both the maxillary and mandibular molars with a corresponding superior head tilt of 10 degrees. The Mandibular anteriors displayed significant inconsistencies in MDAI with both superior and inferior head tilt. A superior head tilt produced a greater change in mesiodistal angulation than did an inferior head tilt.

CONCLUSIONS

Accurately taken panoramic radiographs can serve as a convenient tool for evaluating the MDAI before, during and after orthodontic treatment. Additional radiographs are recommended for the mandibular anteriors.

摘要

目的

在正畸治疗中,全景X线片常用于评估牙齿的近远中轴向倾斜度(MDAI)。这些X线片对因头部位置偏离标准而导致的图像失真很敏感。本研究的目的是测量和量化患者头部位置变化导致的全景X线片上MDAI的变化。

材料与方法

测试装置是一个人类颅骨,沿着每颗牙齿的长轴在牙齿和牙槽突的面部放置导丝。在颅骨的方位与法兰克福水平面平行于地面且分别进行1度、2度、5度、7度和10度的上下旋转时,用数字方式拍摄全景X线片。使用MIPAC软件(DentalEye和LEAD Technologies公司,2005年)确定牙齿的近远中角度。

结果

牙弓中牙齿位置越靠远中,垂直头部位置变化时MDAI的变化就越大。当上颌和下颌磨牙的头部向上倾斜10度时,MDAI的最大变化约为10度。下颌前部在头部上下倾斜时MDAI显示出明显的不一致。头部向上倾斜比向下倾斜在近远中角度上产生的变化更大。

结论

准确拍摄的全景X线片可作为正畸治疗前、治疗期间和治疗后评估MDAI的便捷工具。建议对下颌前部拍摄额外的X线片。