Abstract

Data on the normal depth of insertion of double-lumen tubes have not been published. We studied 101 adult patients undergoing thoracic operations whose tracheas were intubated with a left double-lumen tube. A fiberoptic bronchoscope was introduced into the tracheal lumen, and the tube position was adjusted until the cephalad surface of the bronchial cuff was immediately below the carinal bifurcation. The average depth of insertion for both male and female patients 170 cm tall was 29 cm, and for each 10-cm increase or decrease in height, average placement depth was increased or decreased 1 cm. The correlation between depth of insertion and height was highly significant (P less than 0.0001) for both male and female patients. As depth of DLT insertion at any given height was normally distributed, a technique to confirm correct double-lumen tube position always should be used after initial placement.

摘要

关于双腔管正常插入深度的数据尚未发表。我们研究了101例接受胸科手术且气管插入左双腔管的成年患者。将纤维支气管镜插入气管腔,调整导管位置,直到支气管套囊的头端表面刚好位于隆突分叉下方。身高170cm的男性和女性患者的平均插入深度为29cm,身高每增加或减少10cm,平均放置深度增加或减少1cm。男性和女性患者的插入深度与身高之间的相关性均非常显著(P<0.0001)。由于在任何给定身高下双腔管的插入深度呈正态分布,因此在初始放置后应始终使用一种技术来确认双腔管位置是否正确。