Taguchi Manabu, Zhao Chunfeng, Sun Yu-Long, Jay Gregory D, An Kai-Nan, Amadio Peter C
Orthopedic Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN 55905, USA.
J Hand Surg Am. 2009 Sep;34(7):1276-81. doi: 10.1016/j.jhsa.2009.04.011. Epub 2009 Jun 25.
To investigate the effects of tendon surface treatment using hyaluronic acid (HA) and lubricin on the gliding resistance of human extrasynovial palmaris longus (PL) tendon in vitro.
Thirty-two fresh-frozen cadaver human fingers and 16 ipsilateral PL tendons were used. Each PL tendon was divided into 2 pieces, which were randomly assigned into 4 experimental groups. After the gliding resistance of the normal PL tendon segments were measured, the tendons were treated with either saline, carbodiimide derivatized (cd) gelatin and HA (cd-HA gelatin), cd gelatin with lubricin added (cd gelatin plus lubricin), or cd-HA gelatin plus lubricin. After treatment, tendon gliding resistance was measured during up to 1000 cycles of simulated flexion and extension motion.
The gliding resistance of the PL tendons in the cd-HA gelatin, cd gelatin plus lubricin, and cd-HA gelatin plus lubricin groups was significantly lower than that of the saline-treated control after 1000 cycles. The gliding resistance in these treatment groups decreased within the first 50 cycles and then increased at a much more gradual rate over the 1000 cycles, with the cd-HA gelatin plus lubricin group being most stable.
The results suggest that tendon surface treatment using HA and lubricin can improve the gliding of human PL tendon in vitro. If validated in vivo, tendon surface treatment has the potential to improve the gliding ability of tendon grafts clinically.
研究使用透明质酸(HA)和润滑素对人滑膜外掌长肌腱(PL)体外滑动阻力的影响。
使用32个新鲜冷冻的尸体人类手指和16条同侧PL肌腱。每条PL肌腱分成2段,随机分为4个实验组。在测量正常PL肌腱段的滑动阻力后,肌腱分别用生理盐水、碳二亚胺衍生化(cd)明胶和HA(cd-HA明胶)、添加润滑素的cd明胶(cd明胶加润滑素)或cd-HA明胶加润滑素处理。处理后,在高达1000次模拟屈伸运动循环中测量肌腱滑动阻力。
在1000次循环后,cd-HA明胶组、cd明胶加润滑素组和cd-HA明胶加润滑素组的PL肌腱滑动阻力显著低于生理盐水处理的对照组。这些处理组的滑动阻力在前50次循环内降低,然后在1000次循环中以更缓慢的速率增加,其中cd-HA明胶加润滑素组最稳定。
结果表明,使用HA和润滑素进行肌腱表面处理可改善人PL肌腱在体外的滑动。如果在体内得到验证,肌腱表面处理有可能在临床上提高肌腱移植物的滑动能力。