Department of Applied Physics (Optometry Group), University of Santiago de Compostela, 15706 Santiago de Compostela, Spain.
Ophthalmic Physiol Opt. 2009 Sep;29(5):487-496. doi: 10.1111/j.1475-1313.2009.00634.x. Epub 2009 Jun 30.
Different values of the lower tear meniscus height (TMH) can be obtained depending on the method and technique of measurement employed. This study aimed to assess (1) differences between the absolute (TMH-A), reflex (TMH-R) and fluorescein (TMH-F) lower tear meniscus heights, (2) differences between the central (TMH-R), nasal (TMH-RN) and temporal (TMH-RT) reflex lower tear meniscus heights and (3) the amount of fluorescein present in the lower tear meniscus, 5 min after fluorescein instillation (TMH-FV).
Thirty four young healthy subjects were included in the study. The lower tear meniscus height (TMH) was measured using an eye piece graticule inserted into a slit-lamp.
Mean +/- S.D. values of TMH-A, TMH-R, TMH-RN, TMH-RT, TMH-F and TMH-FV of 0.25 +/- 0.08, 0.13 +/- 0.05, 0.23 +/- 0.06, 0.21 +/- 0.05, 0.27 +/- 0.11 and 0.004 +/- 0.001 mm, respectively were found. The TMH-R was significantly lower than the TMH-A and the TMH-F (p < 0.0001). The TMH-RN and TMH-RT were significantly higher than the TMH-R (p < 0.0001). The TMH-F was significant higher than the TMH-FV (p < 0.0001). No significant differences were found between the TMH-A and TMH-F (p = 0.2), and between the TMH-RN and TMH-RT (p = 0.36).
Careful instillation of fluorescein does not affect normal TMH values. Fluorescein is washed out from the lower tear meniscus 5 min after instillation. Higher values of the TMH can be found at nasal and temporal locations compared to the center of the lower eye lid.
由于测量方法和技术的不同,可能会得到不同的下泪膜月牙高度(TMH)值。本研究旨在评估:(1)绝对 TMH(TMH-A)、反射 TMH(TMH-R)和荧光素 TMH(TMH-F)之间的差异;(2)中央 TMH-R(TMH-RN)、鼻侧 TMH-R(TMH-RN)和颞侧 TMH-R(TMH-RT)之间的差异;(3)荧光素在下泪膜月牙中 5 分钟时的存在量(TMH-FV)。
本研究纳入 34 名年轻健康受试者。使用插入裂隙灯的目镜网格测量下泪膜月牙高度。
TMH-A、TMH-R、TMH-RN、TMH-RT、TMH-F 和 TMH-FV 的平均值(±标准差)分别为 0.25±0.08、0.13±0.05、0.23±0.06、0.21±0.05、0.27±0.11 和 0.004±0.001mm。TMH-R 明显低于 TMH-A 和 TMH-F(p<0.0001)。TMH-RN 和 TMH-RT 明显高于 TMH-R(p<0.0001)。TMH-F 明显高于 TMH-FV(p<0.0001)。TMH-A 和 TMH-F 之间(p=0.2)和 TMH-RN 和 TMH-RT 之间(p=0.36)差异均无统计学意义。
荧光素的小心注入不会影响正常的 TMH 值。荧光素在注入后 5 分钟从下泪膜月牙中冲洗出来。与下眼睑中心相比,鼻侧和颞侧位置的 TMH 值较高。