Suppr超能文献

有限锥形束计算机断层扫描在检测水平根折中的有效性

Effectiveness of limited cone-beam computed tomography in the detection of horizontal root fracture.

作者信息

Kamburoğlu Kivanç, Ilker Cebeci A R, Gröndahl Hans Göran

机构信息

Department of Oral Diagnosis and Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey.

出版信息

Dent Traumatol. 2009 Jun;25(3):256-61. doi: 10.1111/j.1600-9657.2009.00770.x.

Abstract

To compare the diagnostic accuracy of conventional film radiography, charge coupled device (CCD) and photostimulable phosphor plate (PSP) digital images and limited cone-beam computed tomography in detecting simulated horizontal root fracture. Root fractures were created in the horizontal plane in 18 teeth by a mechanical force and fragments were relocated. Another 18 intact teeth with no horizontal root fracture served as a control group. Thirty-six teeth were placed in the respective empty maxillary anterior sockets of a human dry skull in groups three by three. Intraoral radiographs were obtained in three different vertical views by utilizing Eastman Kodak E-speed film, CCD sensor, RVG 5.0 Trophy and a PSP sensor Digora, Optime. Cone beam CT images were taken with a unit (3D Accuitomo; J Morita MFG. Corp, Kyoto, Japan). Three dental radiologists separately examined the intraoral film, PSP, CCD and cone beam CT images for the presence of horizontal root fracture. Specificity and sensitivity for each radiographic technique were calculated. Kappa statistics was used for assessing the agreement between observers. Chi-square statistics was used to determine whether there were differences between the systems. Results were considered significant at P < 0.05. Cone beam CT images revealed significantly higher sensitivities (P < 0.05) than the intraoral systems between which no significant differences were found. Specificities did not show any statistically significant differences between any of the four systems. The kappa values for inter-observer agreement between observers (four pairs) ranged between 0.82-0.90 for the 3DX evaluations and between 0.63-0.71 for the different types of intraoral images. Limited cone beam CT, outperformed the two-dimensional intraoral, conventional as well as digital, radiographic methods in detecting simulated horizontal root fracture.

摘要

比较传统胶片放射摄影、电荷耦合器件(CCD)和光激励荧光板(PSP)数字图像以及有限锥形束计算机断层扫描在检测模拟水平根折方面的诊断准确性。通过机械力在18颗牙齿的水平面上制造根折,并将碎片重新定位。另外18颗无水平根折的完整牙齿作为对照组。将36颗牙齿三三一组放置在人类干燥颅骨的上颌前牙牙槽窝中。使用伊士曼柯达E速胶片、CCD传感器、RVG 5.0 Trophy和PSP传感器Digora Optime在三个不同的垂直视图中获取口内X线片。使用一台设备(3D Accuitomo;日本京都J Morita制造公司)拍摄锥形束CT图像。三位牙科放射科医生分别检查口内胶片、PSP、CCD和锥形束CT图像是否存在水平根折。计算每种放射技术的特异性和敏感性。使用Kappa统计量评估观察者之间的一致性。使用卡方统计量确定各系统之间是否存在差异。结果在P < 0.05时被认为具有显著性。锥形束CT图像显示出比口内系统显著更高的敏感性(P < 0.05),而口内系统之间未发现显著差异。四种系统之间的特异性均未显示出任何统计学上的显著差异。观察者之间(四组)3DX评估的观察者间一致性Kappa值在0.82 - 0.90之间,不同类型口内图像的Kappa值在0.63 - 0.71之间。在检测模拟水平根折方面,有限锥形束CT优于二维口内传统及数字放射摄影方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验