Suppr超能文献

研究中采用拟人模型设计是否会影响 CBCT 诊断牙折的准确性?

Does anthropomorphic model design in studies affect diagnostic accuracy for dental root fracture using CBCT?

机构信息

College of Dentistry, Hawler Medical University, Erbil, Iraq.

Division of Dentistry, School of Medical Science, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Oxford Road, Manchester M13 9PL, UK.

出版信息

Dentomaxillofac Radiol. 2020 Oct 1;49(7):20200093. doi: 10.1259/dmfr.20200093. Epub 2020 Jun 9.

Abstract

OBJECTIVES

The evidence for diagnostic accuracy using cone beam computed tomography (CBCT) for dental applications depends heavily on research, but there is little knowledge of whether the model used affects the diagnostic accuracy results. The objective of this study was to determine the impact of different designs of anthropomorphic models on diagnostic accuracy for the specific task of dental root fracture detection.

METHODS

Horizontal or oblique root fracture was induced in 24 of 48 permanent maxillary incisors. The 48 teeth were scanned by CBCT using standard clinical exposure factors on five occasions, each with a different model design. Scans were viewed by five dental and maxillofacial radiologists, who each made a forced diagnosis of fracture or no fracture in each root and a judgment on root fracture using a five-point confidence scale. Sensitivity (Se), specificity (Sp) and areas under receiver operating characteristic (ROC) curve (Az) were calculated for each observer for each model.

RESULTS

There were no significant differences between the diagnostic accuracy measurements recorded using different models. There were, however, numerous significant differences between observers using the same anthropomorphic model.

CONCLUSIONS

Despite the differences in X-ray attenuation between the five model designs, the results suggest that the anthropomorphic model does not affect the results of diagnostic accuracy studies on root fracture using this CBCT machine at standard clinical exposures. This provides some confidence in the previously published evidence. The interobserver diagnosis differences indicate that research using only two observers could provide misleading results.

摘要

目的

使用锥形束计算机断层扫描(CBCT)进行牙科应用的诊断准确性的证据主要依赖于研究,但对于所使用的模型是否会影响诊断准确性结果知之甚少。本研究的目的是确定不同设计的模拟模型对特定的牙齿根折检测任务的诊断准确性的影响。

方法

在 48 颗上颌恒切牙中的 24 颗牙中诱导水平或倾斜根折。使用标准临床曝光因素,在 5 次扫描中对 48 颗牙齿进行 CBCT 扫描,每次扫描均采用不同的模型设计。5 名口腔颌面放射科医生对扫描进行观察,每位医生在每个牙根中强制诊断骨折或无骨折,并使用 5 分置信度量表对根折进行判断。为每个观察者计算了每个模型的敏感性(Se)、特异性(Sp)和接收器操作特性(ROC)曲线下面积(Az)。

结果

不同模型记录的诊断准确性测量值之间没有显著差异。然而,使用相同模拟模型的观察者之间存在许多显著差异。

结论

尽管五个模型设计之间的 X 射线衰减存在差异,但结果表明,在标准临床曝光下,使用这种 CBCT 机器对根折进行诊断准确性研究时,模拟模型不会影响结果。这为之前发表的证据提供了一些信心。观察者间诊断差异表明,仅使用两名观察者的研究可能会提供误导性结果。

相似文献

本文引用的文献

7
Interpretive Error in Radiology.放射学中的解释性错误。
AJR Am J Roentgenol. 2017 Apr;208(4):739-749. doi: 10.2214/AJR.16.16963. Epub 2016 Dec 27.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验