Lackerbauer Carl-Arnold, Grüterich Martin, Ulbig Michael, Kampik Anselm, Kojetinsky Corina
Department of Ophthalmology, Ludwig-Maximilians-University München, München, Germany.
J Cataract Refract Surg. 2009 Aug;35(8):1343-7. doi: 10.1016/j.jcrs.2009.03.030.
To evaluate the difference between the measured and the intended postoperative central corneal thickness (CCT) by optical low-coherence reflectometry (OLCR) for 3 months after myopic laser in situ keratomileusis (LASIK) and correlate it with refractive outcomes.
Center for Refractive Therapy, Department of Ophthalmology, Ludwig-Maximilians-University Munich, Germany.
The CCT was measured by OLCR before and 6 weeks and 3 months after myopic LASIK. The correlation between the difference in pachymetry and the difference in the measured and planned postoperative refraction was proven by linear regression and Pearson product moment correlation analysis (P<.05). In a subset of eyes with a 7.0 mm optical zone, the effect of the calculated ablation depth on the difference in pachymetry was evaluated. Based on the laser algorithm data, the intended ablation was 100 microm or less in Subgroup 1 and 100 microm or more in Subgroup 2.
Forty-three eyes of 25 patients were evaluated, with 25 eyes in the subset. The difference between the measured and intended postoperative CCT was 11.1 microm +/- 8.1 (SD) at 6 weeks and 13.8 +/- 7.5 microm at 3 months. The correlation between this difference and the difference in refraction was poor (r(2) = 0.005 microm and r(2) = 0.009, respectively). With greater ablation depth (Subgroup 2), the difference in pachymetry decreased by 3 months postoperatively.
The lack of correlation between differences in the measured and intended CCT and the final refraction shows the complexity of intraoperative variables in LASIK and the effect of individual wound healing.
通过光学低相干反射测量法(OLCR)评估近视准分子原位角膜磨镶术(LASIK)术后3个月测量的与预期的中央角膜厚度(CCT)之间的差异,并将其与屈光结果相关联。
德国慕尼黑路德维希 - 马克西米利安大学眼科屈光治疗中心。
在近视LASIK术前、术后6周和3个月通过OLCR测量CCT。通过线性回归和Pearson积矩相关分析(P<0.05)证明测厚差异与测量的和计划的术后屈光度差异之间的相关性。在光学区为7.0 mm的一部分眼睛中,评估计算的消融深度对测厚差异的影响。根据激光算法数据,在第1亚组中预期消融量为100微米或更少,在第2亚组中为100微米或更多。
对25例患者的43只眼睛进行了评估,其中25只眼睛属于该部分。术后6周时测量的与预期的CCT之间的差异为11.1微米±8.1(标准差),术后3个月时为13.8±7.5微米。该差异与屈光度差异之间的相关性较差(r²分别为0.005微米和0.009)。随着消融深度增加(第2亚组),术后3个月时测厚差异减小。
测量的与预期的CCT差异和最终屈光度之间缺乏相关性,表明LASIK术中变量的复杂性以及个体伤口愈合的影响。