Nevado Juan José Berzas, Peñalvo Gregorio Castañeda, Robledo Virginia Rodríguez, Martínez Gabriela Vargas
Department of Analytical Chemistry and Food Technology, University of Castilla-La Mancha, 13071 Ciudad Real, Spain.
Talanta. 2009 Oct 15;79(5):1238-46. doi: 10.1016/j.talanta.2009.05.021. Epub 2009 May 22.
A sensitive and expeditious CE-ESI-MS analytical method for the separation, identification and determination of seven selected antioxidants (cinnamic and benzoic acids), including three isomers of coumaric acid (ortho-, meta- and para-) has been developed. In order to obtain the analytical separation, capillary electrophoresis and CE-MS interface parameters (e.g., buffer pH and composition, sheath liquid and gas flow rates, sheath liquid composition, electrospray voltage, etc.) were carefully optimized. The polar fraction containing the selected phenolic acids was obtained using a previously optimized SPE pretreatment. An MS detector in order to extract structural information about the target compounds and facilitate their qualitative analysis was used in the negative ion mode. The proposed off-line SPE CE-ESI-MS method was validated by assessing its precision, LODs and LOQs, linearity range and accuracy. The optimized and validated method was used in order to quantify the selected antioxidants in various samples of virgin olive oil and extra-virgin olive oil obtained from the main olive varieties cropped in Castilla-La Mancha, Spain. Salicylic acid was used as internal standard throughout in order to ensure reproducibility in the quantitative analysis of the oil samples. The results confirmed the presence of hydroxyphenyl acetic, p-coumaric, ferulic and vanillic acids in substantial amounts (microg g(-1) level) in all samples.
已开发出一种灵敏且快速的毛细管电泳-电喷雾电离质谱(CE-ESI-MS)分析方法,用于分离、鉴定和测定七种选定的抗氧化剂(肉桂酸和苯甲酸),其中包括香豆酸的三种异构体(邻、间和对)。为实现分析分离,对毛细管电泳和CE-MS接口参数(如缓冲液pH值和组成、鞘液和气体流速、鞘液组成、电喷雾电压等)进行了仔细优化。采用先前优化的固相萃取(SPE)预处理方法获得含有选定酚酸的极性馏分。使用质谱检测器在负离子模式下提取目标化合物的结构信息并便于其定性分析。通过评估该方法的精密度、检测限(LOD)、定量限(LOQ)、线性范围和准确度,对所提出的离线SPE CE-ESI-MS方法进行了验证。使用优化和验证后的方法对从西班牙卡斯蒂利亚-拉曼恰种植的主要橄榄品种获得的初榨橄榄油和特级初榨橄榄油的各种样品中的选定抗氧化剂进行定量。始终使用水杨酸作为内标,以确保油样定量分析的重现性。结果证实所有样品中均大量存在(微克/克水平)羟基苯乙酸、对香豆酸、阿魏酸和香草酸。