Enhancement of the non-invasive electroenterogram to identify intestinal pacemaker activity.

作者信息

Ye-Lin Y, Garcia-Casado J, Prats-Boluda G, Ponce J L, Martinez-de-Juan J L

机构信息

Instituto Interuniversitario de Investigación en Bioingeniería y Tecnología Orientada al Ser Humano (I3BH), Universidad Politécnica de Valencia, Spain.

出版信息

Physiol Meas. 2009 Sep;30(9):885-902. doi: 10.1088/0967-3334/30/9/002. Epub 2009 Jul 27.

Abstract

Surface recording of electroenterogram (EEnG) is a non-invasive method for monitoring intestinal myoelectrical activity. However, surface EEnG is seriously affected by a variety of interferences: cardiac activity, respiration, very low frequency components and movement artefacts. The aim of this study is to eliminate respiratory interference and very low frequency components from external EEnG recording by means of empirical mode decomposition (EMD), so as to obtain more robust indicators of intestinal pacemaker activity from the external EEnG signal. For this purpose, 11 recording sessions were performed in an animal model under fasting conditions and in each individual session the myoelectrical signal was recorded simultaneously in the intestinal serosa and the external abdominal surface in physiological states. Various parameters have been proposed for evaluating the efficacy of the method in reducing interferences: the signal-to-interference ratio (S/I ratio), attenuation of the target and interference signals, the normal slow wave percentage and the stability of the dominant frequency (DF) of the signal. The results show that the S/I ratio of the processed signals is significantly greater than the original values (9.66 +/- 4.44 dB versus 1.23 +/- 5.13 dB), while the target signal was barely attenuated (-0.63 +/- 1.02 dB). The application of the EMD method also increased the percentage of the normal slow wave to 100% in each individual session and enabled the stability of the DF of the external signal to be increased considerably. Furthermore, the variation coefficient of the DF derived from the external processed signals is comparable to the coefficient obtained using internal recordings. Therefore, the EMD method could be a very useful tool to improve the quality of external EEnG recording in the low frequency range and therefore to obtain more robust indicators of the intestinal pacemaker activity from non-invasive EEnG recordings.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验