Suppr超能文献

Enhancement of laplacian EEnG from humans by means of an EMD-based method.

作者信息

Garcia-Casado J, Ye-Lin Y, Prats-Boluda G, Guimera J, Alberola J

机构信息

Grupo de Biolectrónica (I3BH), Valencia, Spain.

出版信息

Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:943-6. doi: 10.1109/IEMBS.2010.5627555.

Abstract

Non-invasive recordings of intestinal myoelectrical activity (Electroenterogram, EEnG) are affected by very-low-frequency (VLF) interferences, respiration, ECG and movement artifacts. In order to identify the intestinal pacemaker activity (slow wave), VLF interferences and respiration should be removed from abdominal surface recordings. In this paper a method based on empirical mode decomposition is proposed to identify and cancel such interferences and to enhance external recordings of human EEnG. The study was carried out on 10 recording sessions in which it was acquired 3 surface EEnG signals by means of active laplacian electrodes, together with respiratory and ECG signals. The application of the proposed method permits to increase the signal-to-interference ratio of EEnG signals from - 7.9 ± 3.3 dB to 6.1 ± 2.7 dB. In addition, the method helps to identify the intestinal pacemaker activity from surface EEnG recordings: the dominant frequency of processed signals is 8.6 ± 1.7 cpm which fits the frequency of the intestinal slow wave in the jejunum, whereas the dominant frequency of original signals was 1.6 ± 1.1 cpm which is associated to VLF interferences.

摘要

相似文献

1
Enhancement of laplacian EEnG from humans by means of an EMD-based method.
Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:943-6. doi: 10.1109/IEMBS.2010.5627555.
3
Enhancement of the non-invasive electroenterogram to identify intestinal pacemaker activity.
Physiol Meas. 2009 Sep;30(9):885-902. doi: 10.1088/0967-3334/30/9/002. Epub 2009 Jul 27.
5
Identification of the slow wave of bowel myoelectrical surface recording by empirical mode decomposition.
Conf Proc IEEE Eng Med Biol Soc. 2006;2006:6165-8. doi: 10.1109/IEMBS.2006.260123.
7
Quantification of combined method for interferences reduction in multichannel surface electroenterogram.
Annu Int Conf IEEE Eng Med Biol Soc. 2008;2008:3612-5. doi: 10.1109/IEMBS.2008.4649988.
8
Combined method for artifact reduction in surface electroenterogram.体表小肠电图伪迹减少的联合方法
Annu Int Conf IEEE Eng Med Biol Soc. 2007;2007:1830-3. doi: 10.1109/IEMBS.2007.4352670.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验