Corneal epithelial thickness profile in the diagnosis of keratoconus.

作者信息

Reinstein Dan Z, Archer Timothy J, Gobbe Marine

机构信息

London Vision Clinic, London, United Kingdom.

出版信息

J Refract Surg. 2009 Jul;25(7):604-10. doi: 10.3928/1081597X-20090610-06.

Abstract

PURPOSE

To illustrate the hypothesis that epithelial thickness profile maps could be used as an adjunctive tool to improve the sensitivity and specificity of keratoconus screening by presenting a case series of examples.

METHODS

The Artemis very high-frequency digital ultrasound arc-scanner was used to obtain epithelial thickness profiles in addition to a comprehensive ophthalmic examination to screen for keratoconus. Five case examples are presented; a normal eye, an eye with advanced keratoconus, and three cases where a diagnosis of keratoconus was uncertain based only on the ophthalmic examination.

RESULTS

The epithelial thickness profile in the normal eye was slightly thinner superiorly, consistent with that previously described for a normal population. The keratoconic eye demonstrated an epithelial doughnut pattern of epithelial thinning over the cone surrounded by an annulus of epithelial thickening. In case 1, an epithelial doughnut pattern confirmed the presence of keratoconus in an eye with an abnormal front surface topography. In case 2, the absence of an epithelial doughnut pattern excluded a diagnosis of keratoconus in a patient with an abnormal front surface topography. In case 3, the presence of an epithelial doughnut pattern coincident with an eccentric posterior elevation best-fit sphere indicated a diagnosis of keratoconus. The epithelium appeared to have compensated for the stromal surface cone, resulting in an apparently normal front surface topography.

CONCLUSIONS

An epithelial doughnut pattern appears to indicate the presence of an underlying stromal cone; the lack of an epithelial doughnut pattern would indicate that an abnormal topography was not due to keratoconus. In very early keratoconus, epithelial compensation can mask the presence of an underlying cone on front surface topography, ie, a diagnosis of keratoconus might be missed.

摘要

目的

通过展示一系列病例实例,阐述上皮厚度分布图可作为辅助工具用于提高圆锥角膜筛查的敏感性和特异性这一假说。

方法

除了进行全面的眼科检查以筛查圆锥角膜外,还使用阿耳忒弥斯甚高频数字超声弧形扫描仪获取上皮厚度分布图。展示了五个病例实例;一只正常眼睛、一只患有晚期圆锥角膜的眼睛,以及三个仅根据眼科检查圆锥角膜诊断不确定的病例。

结果

正常眼睛的上皮厚度分布图在上方略薄,与先前针对正常人群描述的情况一致。圆锥角膜眼在圆锥上方呈现上皮变薄的上皮甜甜圈样模式,周围环绕着上皮增厚的环。在病例1中,上皮甜甜圈样模式证实了前表面地形图异常的眼睛中存在圆锥角膜。在病例2中,上皮甜甜圈样模式的缺失排除了前表面地形图异常患者的圆锥角膜诊断。在病例3中,上皮甜甜圈样模式与偏心后凸最佳拟合球体重合表明诊断为圆锥角膜。上皮似乎已经补偿了基质表面的圆锥,导致前表面地形图明显正常。

结论

上皮甜甜圈样模式似乎表明存在潜在的基质圆锥;缺乏上皮甜甜圈样模式表明异常地形图并非由圆锥角膜引起。在非常早期的圆锥角膜中,上皮补偿可掩盖前表面地形图上潜在圆锥的存在,即可能漏诊圆锥角膜。