The use of a hollow polymethylmethacrylate cervical spacer with plating in the treatment of single level cervical disc disease.

作者信息

Chen Jyi-Feng, Wu Chieh-Tsai, Lee Shih-Tseng

机构信息

Department of Neurosurgery, Chang Gung Memorial Hospital, Taipei, Chang Gung University College of Medicine, Taoyuan, Taiwan.

出版信息

Chang Gung Med J. 2009 Jul-Aug;32(4):447-54.

PMID:19664352
Abstract

BACKGROUND

At present, the use of a cervical cage and plating has become an accepted and widely practiced surgical intervention for the treatment of cervical spondylosis and disc herniation. Polymethylmethacrylate (PMMA) bone cement has been used in cervical disc disease as a spacer, with good longterm outcomes, but the method does not result in solid bone fusion in all cases.

METHODS

A prospective study was performed with 92 consecutive patients who underwent single-level anterior cervical discectomy and fusion (ACDF) with a hollow PMMA spacer, cancellous allograft and titanium cervical plate stabilization between January 2002 and December 2003. Patients were followed for a minimum of 2 years.

RESULTS

The surgical procedures used were technically successful for all patients, and there were no major complications related to anesthesia or the overall surgical procedure. The fusion rate was 89.8% at the 12-month follow-up, and 100% at the 24-month follow-up. The mean intervertebral disc height was 6.5 +/- 1.5 mm and regained height was 3.4 +/- 1.3 mm at the 24-month follow- up. The mean segmental lordotic angle was 3.7 +/- 2.0 degrees with an increase of 6.1 +/- 2.3 degrees at the 24-month follow-up. There was no hollow PMMA spacer dislodgment or failure. However, 5 (5.4%) patients had screw loosening and 3 (3.3%) patients underwent a secondary operation for removal of the plate and screws.

CONCLUSIONS

The procedure for a single-level ACDF with a hollow PMMA spacer, cancellous allograft and titanium cervical plate stabilization is safe and effective. There were no complications related to the hollow PMMA spacer. This procedure has a high fusion rate, and can restore disc height and maintain normal cervical lordosis. This method achieves results similar to those of other methods.

摘要

相似文献

1
The use of a hollow polymethylmethacrylate cervical spacer with plating in the treatment of single level cervical disc disease.
Chang Gung Med J. 2009 Jul-Aug;32(4):447-54.
2
Use of a polymethylmethacrylate cervical cage in the treatment of single-level cervical disc disease.
J Neurosurg Spine. 2005 Jul;3(1):24-8. doi: 10.3171/spi.2005.3.1.0024.
3
Anterior decompression and interbody fusion with BAK/C for cervical disc degenerative disorders.采用BAK/C前路减压及椎间融合术治疗颈椎间盘退变疾病。
J Spinal Disord Tech. 2009 Jun;22(4):240-5. doi: 10.1097/BSD.0b013e31816d5f7e.
4
Does rigid instrumentation increase the fusion rate in one-level anterior cervical discectomy and fusion?在单节段颈椎前路椎间盘切除融合术中,使用坚强内固定是否会提高融合率?
Spine J. 2004 Nov-Dec;4(6):636-43. doi: 10.1016/j.spinee.2004.04.010.
5
Modified polymethylmethacrylate cervical plate and screw augmentation technique for intraoperative screw loosening.
J Spinal Disord Tech. 2012 Jun;25(4):235-9. doi: 10.1097/BSD.0b013e3182159790.
6
PMMA versus titanium cage after anterior cervical discectomy - a prospective randomized trial.颈椎前路椎间盘切除术后聚甲基丙烯酸甲酯与钛笼对比——一项前瞻性随机试验
Zentralbl Neurochir. 2007 Feb;68(1):2-7. doi: 10.1055/s-2006-942184.
7
Is anterior cervical fusion with a porous tantalum implant a cost-effective method to treat cervical disc disease with radiculopathy?前路颈椎融合术联合多孔钽植入物治疗伴有根性症状的颈椎病是否具有成本效益?
Spine (Phila Pa 1976). 2012 Sep 15;37(20):1734-41. doi: 10.1097/BRS.0b013e318255a184.
8
Polyetheretherketone (PEEK) cage filled with cancellous allograft in anterior cervical discectomy and fusion.聚醚醚酮(PEEK)椎间融合器填充松质骨异体骨在前路颈椎间盘切除融合术中的应用
Int Orthop. 2008 Oct;32(5):643-8. doi: 10.1007/s00264-007-0378-x. Epub 2007 Jul 17.
9
Hollow cylindrical polymethylmethacrylate strut for spinal reconstruction after single-level cervical corpectomy.用于单节段颈椎椎体次全切除术后脊柱重建的中空圆柱形聚甲基丙烯酸甲酯支柱
J Neurosurg Spine. 2006 Oct;5(4):287-93. doi: 10.3171/spi.2006.5.4.287.
10
Treatment of multilevel cervical fusion with cages.采用椎间融合器治疗多节段颈椎融合术。
Surg Neurol. 2004 Nov;62(5):378-85, discussion 385-6. doi: 10.1016/j.surneu.2004.01.021.

引用本文的文献

1
Comparison of Different Osteobiologics in Terms of Imaging Modalities and Time Frames for Fusion Assessment in Anterior Cervical Discectomy and Fusion: A Systematic Review.前路颈椎间盘切除融合术中不同骨生物材料在融合评估的影像学方式及时间框架方面的比较:一项系统评价
Global Spine J. 2024 Feb;14(2_suppl):141S-162S. doi: 10.1177/21925682231157312.
2
Evaluation of bony fusion after anterior cervical discectomy: a systematic literature review.颈椎前路椎间盘切除术后骨融合的评估:系统文献回顾。
Eur Spine J. 2019 Feb;28(2):386-399. doi: 10.1007/s00586-018-5820-9. Epub 2018 Nov 17.