Area de Radiología y Medicina Física, Facultad de Medicina/Odontología, Universidad de Murcia 30100-Campus de Espinardo, Murcia, Spain.
Med Oral Patol Oral Cir Bucal. 2009 Oct 1;14(10):e499-505. doi: 10.4317/medoral.14.e499.
The European Union has established specific directives concerning radiological protection which are obligatory for member States. In addition, all Spanish dental clinics with radiological equipment are required to have an annual quality control check.
To analyze the effect of new European legislation on dental radiological practice in Spain and to determine whether it has resulted in lower doses being administered to patients.
A total of 10,171 official radiological quality control reports on Spanish dental clinics, covering 16 autonomous regions, were studied following the passing of Royal Decree 2071/1995 on quality criteria in radiodiagnostic installations. The reports, compiled by U.T.P.R Asigma S.A., a company authorised by the Nuclear Safety Council, cover the years 1996 to 2003, which has enabled us to monitor the evolution of radiological procedures in dental clinics over a seven year period.
According to the reports for 2003, 77.3 % of clinics complied with EU requirements, using equipment of 70 kVp, 8 mA, 1.5 mm Al filters, with a collimator length of 20 cm. However, non-compliance was detected in approximately a third (30.8%) of the equipment inspected: alterations in the kilovoltage used, exposure time, performance of the tubing, dosage, linearity/intensity of current and acoustic-luminous signal 6.86%. The mean skin dose reached 3.11 mGy for patients who received an x-ray of an upper molar, representing a decrease of 18% over the seven years studied.
there has obviously been a general improvement in the parameters studied, but only 77.3% of the installations complied fully with official EU regulations concerning dental radiological protection.
欧盟制定了有关辐射防护的具体指令,这些指令对成员国具有约束力。此外,所有配备放射设备的西班牙牙科诊所都需要进行年度质量控制检查。
分析新的欧洲法规对西班牙牙科放射实践的影响,并确定其是否导致患者接受的剂量降低。
在通过关于放射诊断设备质量标准的皇家法令 2071/1995 后,对涵盖 16 个自治区的 10171 份西班牙牙科诊所的官方放射质量控制报告进行了研究。该报告由 U.T.P.R Asigma S.A. 编制,该公司得到核安全委员会的授权,涵盖了 1996 年至 2003 年的报告,这使我们能够在 7 年的时间内监测牙科诊所放射程序的演变。
根据 2003 年的报告,77.3%的诊所符合欧盟要求,使用 70 kVp、8 mA、1.5 毫米 Al 滤波器和 20 厘米长的准直器的设备。然而,在检查的设备中约有三分之一(30.8%)被发现不符合规定:使用的千伏变化、曝光时间、管性能、剂量、电流线性/强度和 6.86%的声-光信号。接受上颌磨牙 X 光检查的患者皮肤剂量平均达到 3.11 mGy,与研究的 7 年相比下降了 18%。
在所研究的参数中显然有了普遍的改善,但只有 77.3%的装置完全符合欧盟关于牙科放射防护的官方规定。