Abstract

INTRODUCTION

Our objective was to compare the effects of 2 preadjusted appliances on angular and linear changes of the mandibular incisors, and transverse mandibular arch dimensional changes over a minimum of 30 weeks. This was a prospective, randomized, controlled, clinical trial a the Royal London Hospital, School of Dentistry, in London and the Kent and Canterbury Hospital in Canterbury, United Kingdom.

METHODS

Sixty- six consecutive patients satisfying the inclusion criteria were enrolled and randomly allocated to treatment with a self-ligating bracket system (SmartClip, 3M Unitek, Monrovia, Calif) and conventional preadjusted edgewise brackets (Victory, 3M Unitek). Initial study models and cephalograms were obtained within a month of starting the trial. All subjects received treatment with the following archwire sequence: 0.016-in round, 0.017 x 0.025-in rectangular, 0.019 x 0.025-in rectangular martensitic active nickel-titanium archwires, and 0.019 x 0.025-in stainless steel archwires. Final records, including study models and a lateral cephalogram, were collected a minimum of 30 weeks after initial appliance placement. Lateral cephalograms were assessed for treatment-related changes in mandibular incisor inclination and position. Transverse dimensional changes in intercanine, interpremolar, and intermolar dimensions, and the amount of crowding alleviated during the study period were assessed by comparison of pretreatment and posttreatment models. All measurements were made with a digital caliper (150 mm ISO 9001 electronic caliper, Tesa Technology, Renens, Switzerland).

RESULTS

Sixty patients completed the study. After adjustment for pretreatment values, duration of treatment, and amount of crowding alleviated during the study period, bracket type had little effect on incisor inclination (P = 0.437) and positional changes (P = 0.35), and intercanine (P = 0.967), inter-first premolar (P = 0.495), and inter-second premolar (P = 0.905) dimensions. However, the self-ligating appliance produced slightly more expansion in the molar region, a difference that was statistically significant (P = 0.009). Pretreatment values for incisor inclination (P = 0.044) and transverse dimensions (P = 0.000) affected inclination and transverse changes, respectively, with proclination less likely when the labial segment was proclined at the outset and expansion unlikely during leveling and alignment in wider arches. Greater alleviation of crowding during the study period resulted in more incisor proclination (P = 0.000) and advancement (P = 0.000).

CONCLUSIONS

There was little difference overall in the pattern of arch alignment and leveling related to the 2 preadjusted appliances. However, there was a statistically greater increase in intermolar width in the group treated with the self-ligating appliance, although the difference was only 0.91 mm.

摘要

引言

我们的目的是比较两种预调整矫治器对下颌切牙角度和线性变化以及下颌牙弓横向尺寸变化的影响,观察期至少为30周。这是一项前瞻性、随机、对照临床试验,在伦敦皇家伦敦医院牙科学院以及英国坎特伯雷的肯特和坎特伯雷医院进行。

方法

连续纳入66例符合纳入标准的患者,并随机分配接受自锁托槽系统(SmartClip,3M Unitek,美国加利福尼亚州蒙罗维亚)和传统预调整方丝弓托槽(Victory,3M Unitek)治疗。在试验开始后一个月内获取初始研究模型和头影测量片。所有受试者均接受以下弓丝序列治疗:0.016英寸圆丝、0.017×0.025英寸矩形丝、0.019×0.025英寸矩形马氏体活性镍钛弓丝以及0.019×0.025英寸不锈钢弓丝。在最初佩戴矫治器至少30周后收集最终记录,包括研究模型和头颅侧位片。对头影测量片评估下颌切牙倾斜度和位置的治疗相关变化。通过比较治疗前和治疗后的模型,评估尖牙间、第一前磨牙间、第二前磨牙间横向尺寸变化以及研究期间拥挤缓解量。所有测量均使用数字卡尺(150 mm ISO 9001电子卡尺,瑞士雷嫩市泰萨技术公司)。

结果

60例患者完成了研究。在对治疗前值、治疗持续时间以及研究期间拥挤缓解量进行校正后,托槽类型对切牙倾斜度(P = 0.437)和位置变化(P = 0.35)以及尖牙间(P = 0.967)、第一前磨牙间(P = 0.495)和第二前磨牙间(P = 0.905)尺寸影响不大。然而,自锁矫治器在磨牙区产生的扩弓量略多,差异具有统计学意义(P = 0.009)。切牙倾斜度(P = 0.044)和横向尺寸(P = 0.000)的治疗前值分别影响倾斜度和横向变化,初始时唇侧段前倾则前倾的可能性较小,在较宽牙弓整平排齐过程中扩弓的可能性也较小。研究期间拥挤缓解程度越大,切牙前倾(P = 0.000)和前移(P = 0.000)越明显。

结论

两种预调整矫治器在牙弓排齐整平模式上总体差异不大。然而,接受自锁矫治器治疗组的磨牙间宽度在统计学上有更大增加,尽管差异仅为0.91 mm。