Sarnthein Johannes, Andersson Maria, Zimmermann Michael B, Zumsteg Dominik
Neurochirurgische Klinik, UniversitätsSpital Zürich, CH-8091 Zürich, Switzerland.
Clin Neurophysiol. 2009 Oct;120(10):1835-40. doi: 10.1016/j.clinph.2009.08.014. Epub 2009 Sep 16.
The inter-individual variation in the shape of a visual evoked potential (VEP) is large even for simple stimuli. We compared the inter-individual variation in VEP waveform to the intra-individual stability.
We recorded VEP with checkerboard stimulation in 10 women aged 19-29years in two sessions. We determined the latencies and the peak-to-peak amplitude of N75 and P100. As a new approach in VEP research, we regressed VEP waveforms pairwise onto each other and calculated a t-value between all sessions. The maximal t-value was taken to indicate recognition for all 19 comparisons performed with one session. The recognition rate was cross-validated in a generalized linear regression model (GLM).
The number of sessions correctly matched to the correct subject was 19 of 20 (true positives) leading to a sensitivity of 95.0% with confidence interval [75.1% 99.9%] for the method. The number of true negatives was 359 of 360 leading to a specificity of 99.7% [98.5% 100.0%].
The VEP waveform shows high intra-individual stability compared to the inter-individual variation in healthy women.
With a new statistical approach the effect of external factors on the VEP waveform can now be contrasted against the normal variability over time in longitudinal studies.
即使对于简单刺激,视觉诱发电位(VEP)形状的个体间差异也很大。我们将VEP波形的个体间差异与个体内稳定性进行了比较。
我们对10名年龄在19至29岁之间的女性进行了两次棋盘格刺激下的VEP记录。我们确定了N75和P100的潜伏期以及峰峰值幅度。作为VEP研究中的一种新方法,我们将VEP波形两两进行相互回归,并计算所有记录之间的t值。取最大t值来表示在一次记录中进行的所有19次比较的识别情况。识别率在广义线性回归模型(GLM)中进行交叉验证。
正确匹配到正确受试者的记录次数为20次中的19次(真阳性),该方法的灵敏度为95.0%,置信区间为[75.1% 99.9%]。真阴性次数为360次中的359次,特异性为99.7% [98.5% 100.0%]。
与健康女性的个体间差异相比,VEP波形显示出较高的个体内稳定性。
通过一种新的统计方法,现在可以在纵向研究中将外部因素对VEP波形的影响与随时间的正常变异性进行对比。