Division of Endodontics, Department of Preventive and Restorative Dental Sciences, University of California School of Dentistry, San Francisco, California 94143-0758, USA.
J Endod. 2009 Nov;35(11):1584-8. doi: 10.1016/j.joen.2009.07.018.
The purpose of this study was to assess canal preparation outcomes in vitro by novice clinicians after standardized teaching sessions.
All students received a training session. In experiment 1, twenty canals of mandibular molars were prepared with GT and ProTaper rotaries by 10 students. Standardized radiographs were exposed before and after canal preparation, and canal curvature was measured; canals were assessed for patency and preparation time. In experiment 2, mandibular molars (20 canals) were submitted to microcomputed tomography before and after canal preparation with ProTaper and GT rotaries by 2 dental students. Canals were metrically assessed for changes (volume, surface, cross-sectional shape, transportation) during canal preparation by using software.
In experiment 1, canal curvature decreased by 7.6 degrees and 7.8 degrees for GT and ProTaper preparations; there were no broken instruments, and 2 canals lost patency. The time for GT preparation was longer than for ProTaper (29.7 +/- 6.8 vs 19.4 +/- 8.1 minutes, P <.05). In experiment 2, canal volumes and surface areas increased (P < .001), and prepared canals were rounder in cross-section and more tapered. Mean canal transportation ranged between 0.14 +/- 0.05 mm and 0.23 +/- 0.09 mm for apical and coronal canal thirds. There were no significant differences between the instruments or the operators regarding center of mass shifts; qualitative and quantitative data for canal transportation were similar to earlier studies with experienced operators.
Both rotary instruments performed adequately with inexperienced operators who received a brief structured training session.
本研究旨在评估经过标准化教学后,新手临床医生在体外进行根管预备的效果。
所有学生都接受了培训课程。在实验 1 中,10 名学生使用 GT 和 ProTaper 根管预备器械对 20 个下颌磨牙根管进行预备。在根管预备前后拍摄标准化射线照片,并测量根管弯曲度;评估根管通畅度和预备时间。在实验 2 中,由 2 名牙科学生使用 ProTaper 和 GT 根管预备器械对下颌磨牙(20 个根管)进行根管预备前后的 microCT 检查。使用软件对根管预备过程中的根管进行度量评估,以评估变化(体积、表面、横截面形状、偏移)。
在实验 1 中,GT 和 ProTaper 预备后的根管弯曲度分别降低了 7.6 度和 7.8 度;没有器械折断,有 2 个根管失去了通畅度。GT 预备时间长于 ProTaper(29.7 +/- 6.8 比 19.4 +/- 8.1 分钟,P <.05)。在实验 2 中,根管体积和表面积增加(P <.001),预备后的根管横截面更圆,锥度更大。根尖和根管冠三分之一的平均根管偏移范围在 0.14 +/- 0.05 毫米和 0.23 +/- 0.09 毫米之间。对于质量中心的移动,两种器械和两位操作者之间没有显著差异;根管偏移的定性和定量数据与经验丰富的操作者进行的早期研究相似。
两种旋转器械都能被接受过简短结构化培训课程的无经验操作人员有效地使用。