Suppr超能文献

基于 ICH 指南 Q2 的电子舌性能确认

Performance qualification of an electronic tongue based on ICH guideline Q2.

机构信息

Institute of Pharmaceutics and Biopharmaceutics, Heinrich-Heine-University Duesseldorf, Universitaetsstr. 1, 40225 Duesseldorf, Germany.

出版信息

J Pharm Biomed Anal. 2010 Feb 5;51(3):497-506. doi: 10.1016/j.jpba.2009.09.029. Epub 2009 Sep 27.

Abstract

Recent progress in sensor technology has led to the development and application of electronic taste sensing systems. Especially taste prediction of pharmaceutical formulations is a matter of particular interest and is increasingly performed using electronic tongues. Several studies have dealt with electronic tongues before, but an analytical approach describing successfully conducted qualification has not been reported yet. Performance qualification of the taste sensing system SA402B (Insent Inc., Atsugi-chi, Japan) equipped with seven lipid membrane sensors was undertaken with special regard to bitter taste assessment. These sensors represent the gustatory stimuli bitterness, umami, saltiness, sourness, and the nociceptive sensation astringency. Specificity, linearity, range, accuracy, precision, detection and quantitation limit as well as robustness were established for each sensor type referring to ICH guideline Q2 (R1). Some items mentioned in the guideline were applicable whereas others had to be modified due to differences of the system to other commonly used analytical techniques. Quinine hydrochloride being one of the bitterest drugs served as model substance. A large range of linearity (0.01-100mM) with corresponding precision (RSD<4%) was found for most sensors. One sensor had a lower detection threshold (0.0025mM) for quinine hydrochloride than humans typically have. Different methods for determination of detection and quantitation limits were implemented and discussed with respect to rationality and feasibility. Therefore the approach based on visual evaluation was found as most adequate. An adapted guidance following ICH guideline Q2 was developed serving qualification of taste sensing systems in the future.

摘要

近年来,传感器技术的进步推动了电子味觉传感系统的开发和应用。特别是药物配方的味觉预测,是一个特别引人关注的领域,越来越多的电子舌被用于这项工作。之前已经有一些关于电子舌的研究,但尚未有报道成功进行分析方法学确证的案例。本文对 Insent 公司(日本绫部市)的 SA402B 味觉传感系统进行了性能确证,该系统配备了 7 个脂质膜传感器,特别用于苦味评估。这些传感器代表了味觉刺激苦味、鲜味、咸味、酸味和刺激性收敛味。参照 ICH 指南 Q2(R1),我们对每种传感器类型建立了专属性、线性、范围、准确度、精密度、检测限、定量限和耐用性。该指南中的一些项目是适用的,而其他项目由于系统与其他常用分析技术的差异,需要进行修改。奎宁盐酸盐是最苦的药物之一,被用作模型物质。大多数传感器具有较大的线性范围(0.01-100mM)和相应的精密度(RSD<4%)。其中一个传感器对奎宁盐酸盐的检测下限(0.0025mM)低于人类通常的味觉感知。本文还讨论了不同的检测限和定量限确定方法的合理性和可行性,发现基于视觉评估的方法最为合适。本文开发了一种适应性指南,遵循 ICH 指南 Q2,以用于未来的味觉传感系统性能确证。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验