The mechanisms of early cellular recruitment and interaction to titanium implants are not well understood. The aim of this study was to investigate the expression of pro-inflammatory cytokines, chemokines and adhesion markers during the first 24 h of implantation. Anodically oxidized and machined titanium implants were inserted in rat tibia. After 3, 12, and 24 h the implants were unscrewed and analyzed with quantitative polymerase chain reaction. Immunohistochemistry and scanning electron microscopy revealed different cell types, morphology and adhesion at the two implant surfaces. A greater amount of cells, as indicated by higher expression of small subunit ribosomal RNA (18S), was detected on the oxidized surface. Higher expression of CXC chemokine receptor-4 (at 12 h) and integrins, alphav (at 12 h), beta1 (at 24 h) and beta2 (at 12 and 24 h) was detected at the oxidized surfaces. Significantly higher tumor necrosis factor-alpha (at 3 h) and interleukin-1beta (at 24 h) expression was demonstrated for the machined surface. It is concluded that material surface properties rapidly modulate the expression of receptors important for the recruitment and adhesion of cells which are crucial for the inflammatory and regenerative processes at implant surfaces in vivo.
早期细胞募集和相互作用到钛植入物的机制尚不清楚。本研究旨在探讨植入后 24 小时内促炎细胞因子、趋化因子和黏附标志物的表达。阳极氧化和机械加工的钛植入物插入大鼠胫骨中。在 3、12 和 24 小时后,拧下植入物并进行定量聚合酶链反应分析。免疫组织化学和扫描电子显微镜显示了两种植入物表面不同的细胞类型、形态和黏附。通过小亚基核糖体 RNA(18S)的高表达表明,氧化表面上检测到更多的细胞。在氧化表面上检测到更高的 CXC 趋化因子受体-4(在 12 小时)和整合素,alphaV(在 12 小时)、beta1(在 24 小时)和 beta2(在 12 和 24 小时)的表达。在机械加工表面上,肿瘤坏死因子-α(在 3 小时)和白细胞介素-1β(在 24 小时)的表达显著更高。结论是,材料表面特性迅速调节对细胞募集和黏附至关重要的受体的表达,这对体内植入物表面的炎症和再生过程至关重要。