Suppr超能文献

后半规管堵塞手术后的听力和前庭功能

Hearing and vestibular functions after plugging surgery for the posterior semicircular canal.

作者信息

Seo Toru, Hashimoto Misako, Saka Naoki, Sakagami Masafumi

机构信息

Department of Otolaryngology, Hyogo College of Medicine, Nishinomiya, Hyogo, Japan.

出版信息

Acta Otolaryngol. 2009 Nov;129(11):1148-52. doi: 10.3109/00016480802609582.

Abstract

CONCLUSIONS

Results of audiometry, caloric testing and vestibular evoked myogenic potential (VEMP) testing were hardly influenced by plugging surgery.

OBJECTIVE

To evaluate the influence of surgical plugging of the posterior semicircular canal on inner ear function in patients with benign paroxysmal positional vertigo (BPPV).

SUBJECTS AND METHODS

The subjects were five consecutive patients with intractable BPPV who underwent plugging surgery. The following functions of the inner ear were examined before and 6 months after surgery. Cochlea function was evaluated by the average hearing level of three frequencies (500, 1000 and 2000 Hz), that of the semicircular canal by canal paresis percent (CP%) in caloric testing and that of the otolith by the left-right difference ratio on VEMP testing.

RESULTS

Positional vertigo was resolved in all patients. One subject was completely deaf before and after surgery. The average hearing level did not change more than 10 dB after surgery in the other four cases. CP% did not worsen more than 10% in any case. The VEMP results after surgery did not change more than 10% from before surgery in any case.

摘要

结论

听力测定、冷热试验及前庭诱发肌源性电位(VEMP)测试结果几乎不受填塞手术的影响。

目的

评估后半规管手术填塞对良性阵发性位置性眩晕(BPPV)患者内耳功能的影响。

对象与方法

选取5例连续接受填塞手术的难治性BPPV患者。于术前及术后6个月检查内耳的以下功能。通过三个频率(500、1000和2000赫兹)的平均听力水平评估耳蜗功能,通过冷热试验中的半规管轻瘫百分比(CP%)评估半规管功能,通过VEMP测试中的左右差异率评估耳石功能。

结果

所有患者的位置性眩晕均得到缓解。1例患者术前术后均完全失聪。其他4例患者术后平均听力水平变化不超过10分贝。在任何情况下,CP%恶化均不超过10%。在任何情况下,术后VEMP结果与术前相比变化均不超过10%。