J Biomed Opt. 2009 Sep-Oct;14(5):054027. doi: 10.1117/1.3253318.
We present a quantitative near-IR spectroscopy study of the absolute values of oxygen saturation of hemoglobin before and after surgically induced testicular torsion in adult rabbits. Unilateral testicular torsions (0, 540, or 720 deg) on experimental testes and contralateral sham surgery on control testes are performed in four adult rabbits. A specially designed optical probe for measurements at multiple source-detector distances and a commercial frequency-domain tissue spectrometer are used to measure absolute values of testicular hemoglobin saturation. Our results show: (1) a consistent baseline absolute tissue hemoglobin saturation value of 78+/-5%, (2) a comparable tissue hemoglobin saturation of 77+/-6% after sham surgery, and (3) a significantly lower tissue hemoglobin saturation of 36+/-2% after 540- and 720-deg testicular torsion surgery. Our findings demonstrate the feasibility of performing frequency-domain, multidistance near-IR spectroscopy for absolute testicular oximetry in the assessment of testicular torsion. We conclude that near-IR spectroscopy has potential to serve as a clinical diagnostic and monitoring tool for the assessment of absolute testicular hemoglobin desaturation caused by torsion, with the possibility of serving as a complement to conventional color and spectral Doppler ultrasonography.
我们进行了一项定量近红外光谱研究,以测量成年兔手术诱导睾丸扭转前后血红蛋白氧饱和度的绝对值。在四只成年兔中,对实验睾丸进行单侧睾丸扭转(0、540 或 720 度),对对照睾丸进行对侧假手术。使用专门设计的用于在多个源-探测器距离处进行测量的光学探头和商业频域组织光谱仪来测量睾丸血红蛋白饱和度的绝对值。我们的结果表明:(1)基线组织血红蛋白饱和度的一致绝对值为 78+/-5%,(2)假手术后组织血红蛋白饱和度相当,为 77+/-6%,(3)540 和 720 度睾丸扭转手术后,组织血红蛋白饱和度显著降低,为 36+/-2%。我们的发现证明了在评估睾丸扭转时进行频域、多距离近红外光谱绝对睾丸血氧测定的可行性。我们得出结论,近红外光谱有可能成为评估扭转引起的绝对睾丸血红蛋白饱和度降低的临床诊断和监测工具,有可能作为传统彩色和频谱多普勒超声的补充。